Product finder
Product code
Application
Environment
Device
Category
Product
Type
Product finder

Find the right E2S product

Search

D1xS1F 115dB(A) Alarm Horn Sounder 1-22-140

Product Image
Product Image
Product Image
The D1xS1F is a high performance globally certified alarm horn sounder featuring a sound output of up to 115dB(A). The robust Type 4/4X, IP66 marine grade, corrosion proof aluminium enclosure is approved for Class I & II Div 1, Zone 1 & 20, IECEx and ATEX Zone 1, 2, 21 & 22 explosion proof signalling applications.
Request a quote for this product
Voltage
Cable entries
Stopping plug/adaptor material
Bracket material
Product version
Product option
Enclosure colour
Part Number:
D1xS1F
Request Price or enquire about this product
Enquire about
115dB(A) Alarm Horn Sounder

Upgraded Product

  • New D Class amplifier technology
  • Reduced in-rush
  • A4 316 stainless steel bracket as standard
  • Tropicalised electronics
  • New stage activation and line monitoring capability

Description

Featuring 64 alarm tones with 4 remotely activated stage/channels. The threaded flameproof joint, multiple cable entries and duplicated, pluggable termination simplifies both installation and routine maintenance. The 24Vdc version is EN54-3 EU, UK CPR, MED and MER compliant plus UL464 NFPA compliant for public mode fire alarm use, the 100-240Vac version for general signalling use. SIL1 & SIL2 Route 2H to IEC61508 (2010), with optional diagnostics for Route 1H SIL2 compliance.

Downloads

Datasheet Datasheet.pdf
Install manual: Product version [A] D190-01-001-IS_Issue_9__D1xS1-A_.pdf
Install manual: Product version [S] D190-01-651-IS_Issue_4__D1xS1-S_SIL2_.pdf
Install manual: Product version [D] D190-01-051-IS_Issue_4__D1xS1-D_.pdf
-Install manual Telephone-Relay version [T] D190-01-681-IS_Issue_2__D1xS1-T_.pdf
CSFM Listing CSFM_Listing_2279-0506_D1xS__D1xC_2025.pdf
Installation manual - Chinese D190-00-001-IS-CHN_Issue_2__D1xS1_.pdf
IECEx certificate IECEx_ULD_19.0008X_002_D1xC_S_L.pdf
ATEX certificate DEMKO_19_ATEX_2141X_Issue_2_D1xC_S_L.pdf
UL certificate of compliance UL_CoC_20150818-E230764_Vol1Sec3__D1xS-C_.pdf
UKCA Certificate UL21UKE2132X_Rev1_D1xC_S_L.pdf
EC CPR Certificate 2831-CPR-F4858_-1-D1xS1F.pdf
UK CPR Certificate 0832-UKCA-CPR-F1782-1-D1xS1F.pdf
CCCEx Certificate EN CCCEx_Certificate_EN_Iss001_D1xS1_2027.03.28.pdf
CCCEx Certificate CN CCCEx_Certificate_CN_Iss001_D1xS1_2027.03.28.pdf
CCOE PESO COOE_P576154_D1xS_D1xC_D1xL.pdf
MED certificate MEDB000085K.pdf
DNV Type Approval TAA00003DF.pdf
MER certificate MERB000085K.pdf
ECAS Ex Approval 24-06-114451_E24-06-118027_NB0007_D1xS-L.pdf
Ingress Protection certificate TL23065B_E2S_IP66_and_IPX7.pdf
Declaration of Conformity DC-067_Issue_K_D1x.pdf
Declaration of Conformity UKCA DC-097_Issue_C_D1x_UKCA.pdf
SIL Certificate: Product version [A] T1072-215-2_SIL2_SIL1_2H.pdf
SIL Certificate: Product version [S] T1023-198_SIL2_1H.pdf
Declaration of Performance DP_-_2831-CPR-F4858-Issue_B_D1xS1FDC024.pdf
2D drawing (PDF) D190-05-001_Issue_C.pdf
2D drawing (DWG) D190-05-001_Issue_C.dwg
3D drawing (STEP) D190-05-001-3D_Issue_1.STEP
Wiring Schematic DC voltage D190-06-001_Issue_3.pdf
Wiring Schematic AC voltage D190-06-005_Issue_1.pdf
Wiring schematic: Product version [S] D190-06-651_Issue_2_DC.pdf
Nameplate Drawing D190-09-001_Issue_3.pdf
Equipment Tag Drawing D254-00-101_Issue_1.pdf
Duty Label Drawing D254-00-001_Issue_1.pdf
Pole Mount & Sun Shade Drawing D217-05-061_Issue_2__D1xS1F_L1F_.pdf

Features

  • Maximum sound pressure level output of 115dB(A)
  • Choice of 64 alarm tone frequencies
  • 4 remotely selectable alarm stages/channels
  • Positive or negative line stage/channel switching
  • Automatic synchronisation on multi-sounder system
  • Ratchet adjustable 316 stainless steel bracket
  • Triple cable entries
  • Robust marine grade aluminium enclosure
  • EN54-3 tested – EU & UK CPR compliant
  • UL464 Public mode fire alarm use
  • CAN/ULC S525 Audible Signaling Devices for Fire Alarm

Specification

Maximum output: 115dB(A) @ 1 metre [106dB(A) @ 10ft/3m]
Class II version: 98dB(A) @ 1 metre [88dB(A) @ 10ft/3m]
Nominal output: 110dB(A) @ 1m +/- 3dB – Tone 4 [101dB(A) @ 10ft/3m]
Class II version: 94dB(A) @ 1 metre [84dB(A) @ 10ft/3m]
No. of tones: 64 (UKOOA / PFEER compliant)
No. of stages: 4
Volume control: Full range
Effective range: 125m/410ft @ 1KHz
Voltages DC: 24Vdc (11.5-54Vdc)
Voltages AC: 230Vac (100-240Vac)
In-rush: 815mA within 4ms @ 24Vdc
Stage switching: DC units: positive or negative
AC units: common supply line
Safety Integrity Level: Product version A: SIL1 and SIL2 Route 2H
Product version S: SIL2 Route 1H with diagnostics SFF: >99%
See install manual for reliability & functional safety data
Ingress protection: EN60529: IP66/67
UL50E / NEMA250: 4 / 4X / 3R / 13
Enclosure material: Marine grade LM6 aluminium alloy
Enclosure colour: Red or Grey, custom colours available on request
Enclosure finish: Chromate & powder coated finish
Cable entries: 1×1/2"NPT & 2xM20
Thread adaptors available
Stopping plugs: Brass, Nickel Plated or Stainless Steel
Terminals: 0.5 – 2.5mm² (20-14AWG) – 12AWG solid core conductor
Pluggable & duplicated terminals
Line monitoring: Blocking diode included
EOL Min. 500 Ohm 2W, or 3k3 Ohm 0.5W resistor
or diode (DC versions) can be fitted
Ground/Earth stud: M5
Enclosure volume: <2 litres
Installation temp: -55 to +85°C [-67° to +185°F]
Storage temp: -55 to +85°C [-67° to +185°F]
Relative humidity: 99%
Vibration test: 35Hz for a duration 4Hr (UL464)
Jarring test: 3ft/lb Energy (UL464)
Impact test: 3x 5lb (UL464)
MTBF DC: 225.16 years / 1,972,386 hours – MIL 217
MTBF AC: 138.96 years / 1,217,285 hours – MIL 217
Weight: 4.00kg/8.80lbs

Current Consumption

Nominal
Voltage:
Voltage
range:
Nominal
current:
Max.
current:
In-rush:
12Vdc 11.5-54Vdc 221mA 221mA -
24Vdc 11.5-54Vdc 185mA 221mA 815mA <4ms
48Vdc 11.5-54Vdc 115mA 221mA -
115Vac 50/60Hz 100-260V ac 73mA 80mA -
230Vac 50/60Hz 100-260V ac 48mA 80mA -

Part Codes

Part Code: Identifier: Description:
Product type: D1xS1 D1xS1 alarm horn sounder
Horn type: F Flare re-entrant horn
Voltage: DC024
AC230
11.5-54Vdc
100-240Vac
Cable entries:[e] A
B
C
D
F
G
Note:
2 x M20x1.5mm & 1 × 1/2"NPT
2 × 1/2"NPT – adaptors
2 × 3/4"NPT – adaptors
2 x M25x1.5mm – adaptors
1 × 3/4"NPT – adaptor
1 x M25x1.5mm – adaptor
All entries, excluding thread adaptors, supplied with stopping plugs installed.
Stopping plug/
adaptor material: [m]
B
N
S
Brass
Nickel plated brass
Stainless steel
Bracket material: [s] 1
3
5
A4 316 Stainless Steel
A4 316 St/St with Equip. Tag
A4 316 St/St with Equip. Tag and Duty Label
Product version: [v] A

D
S

T
UL, cUL, ULC, IECEx, ATEX, CCCEx, PESO, CSFM, MED, MER – SIL1 & SIL2 Route 2H
Class II – UL, cUL
UL, cUL, ULC, IECEx, ATEX, CCCEx, PESO, CSFM
SIL2 Route 1H with diagnostics SFF: >99%
IECEx, ATEX, PESO – Telephone/Relay initiate
Product option:
[o]
1
Z
X
Y
K
V
Standard product
Custom alarm tone software – contact E2S
Custom configuration – contact E2S
Stage control Config. 4
Stage control Config. 5 (DC) and Config. 2 (AC)
Stage control Config. 6
Enclosure colour: [x] R
G
S
Red
Grey
Special colour – contact E2S
Note:
For UK & EU CPR, MED, MER compliant 24Vdc variant, select product version A and product option 1
Accessories:
SP65-0001-A4
SP65-0003-A4
Pole Mount Bracket Kit St/St A4 (316)
Sunshade – St/St A4 (316)
Alarm stage control:
Please review the installation manual and wiring schematics for remote stage control and EOL resistor monitoring configuration options:
Config. 1 [DC]: Factory default. Common negative, positive switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only
Config. 2 [DC]: User setting. Common positive, negative switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only
Config. 3 [DC]: User setting. Common negative, positive switching activation of Alarm Stages 1 & 2 with EOL on both stages. Reverse polarity monitoring
Config. 4 [DC]: Product option ‘Y’. Independent activation of Alarm Stages 1 & 2 with EOL on both stages. Forward polarity monitoring
Config. 5 [DC]: Product option ‘K’. Horn continuously powered. Voltage free activation of up to 3 alarm stages
Config. 6 [DC]: Product option ‘V’. Independent activation of up to 4 Alarm Stages with EOL on all stages. Forward polarity monitoring
Config. 1 [AC]: Factory default. Up to 4 Alarm Stages. Stage 1 activated at power on. Stages 2, 3 and 4 via volt free contacts
Config. 2 [AC]: Product option ‘K’. Horn continuously powered. Voltage free activation of up to 3 alarm stages

Approvals

  • UL/cUL/ULC File ref: E230764
  • IECEx Certificate: IECEx ULD 19.0008X
  • ATEX Certificate: DEMKO 19 ATEX 2141X
  • CSFM listing: 7136-2279:0506
  • UKCA certificate: UL21UKEX2132X
  • CCCEx certificate: 2022122310115173
  • EU CPR certificate: 2831-CPR-F4858
  • UK CPR certificate: 0832-UKCA-CPR-F1782
  • MED certificate: MEDB000085K
  • MER certificate: MERB000085K
  • SIL1 & SIL2 compliant to IEC61508 (2010)

Assemblies

The D1xS1F is available as a plated assembly configured with Xenon strobe or LED beacons with or without a D1xJ2 Ex d junction box.
Contact E2S for further information.

Coding

  • NEC / CEC Class / Zone
    Class I Zone 1 IIC T5 Ta -55°C to +85°C (T6 +75°C)
  • NEC / CEC Class / Div
    Class I Div 1 ABCD T5 Ta -55°C to +85°C (T6 +75°C)
  • IECEx / ATEX
    II 2G Ex db IIC T5 Gb Ta -55°C to +75°C (T6 +70°C)
    II 2D Ex tb IIIC T82°C Db Ta ‐55°C to +75°C
  • Product version: D: NEC / CEC Class / Zone
    Zone 20 IIIB Ta -55°C to +70°C
  • Product version: D: NEC / CEC Class / Div
    Class II Div 1 FG T6 Ta -55°C to +70°C
    Class III Div 1 Ta -55°C to +70°C
    See product manual for full voltage specific coding.

Tone Table

Stage 1 WAV file Frequency Description. Stage 2 Stage 3 Stage 4
T 1 /system/1/assets/files/000/000/405/405/214ccf82a/original/TF037.WAV 1000 Continuous – PFEER Toxic Gas Any T 2 T 44
T 2 /system/1/assets/files/000/000/386/386/ceb4e488c/original/TF009.WAV 1200/500 @ 1Hz Sweeping – DIN / PFEER P.T.A.P. Any T 3 T 44
T 3 /system/1/assets/files/000/000/412/412/fa8b418f9/original/TF045.WAV 1000 @ 0.5Hz (1s on, 1s off) Intermittent – PFEER Gen. Alarm Any T 2 T 44
T 4 /system/1/assets/files/000/000/383/383/11797b764/original/TF019.WAV 1.4KH-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s – NF C 48-265 Any T 24 T 1
T 5 /system/1/assets/files/000/000/382/382/2c2978b6a/original/TF017.WAV 544(100mS)/440 (400mS) – NF S 32-001 Any T 19 T 1
T 6 /system/1/assets/files/000/000/947/947/8f040484a/original/TF053.wav 1500/500 – (0.5s on , 0.5s off) x3 + 1s gap – AS4428 Any T 44 T 1
T 7 /system/1/assets/files/000/000/944/944/890010fd0/original/TF054.wav 500-1500Hz Sweeping 2 sec on 1 sec off – AS4428 Any T 44 T 1
T 8 /system/1/assets/files/000/000/417/417/abf396de0/original/TF003.WAV 500/1200Hz @ 0.26Hz(3.3s on, 0.5s off) – NEN 2575 Any T 24 T 35
T 9 /system/1/assets/files/000/000/953/953/5deedc543/original/TF055.wav 1000 (1s on, 1s off)x7 + (7s on, 1s off) – IMO Code 1a Any T 34 T 1
T 10 /system/1/assets/files/000/000/952/952/3a041fde3/original/TF056.wav 1000 (1s on, 1s off)x7 + (7s on, 1s off) – IMO Code 1a Any T 34 T 1
T 11 /system/1/assets/files/000/000/946/946/761de34c6/original/TF057.wav 420(0.5s on, 0.5s off)x3 + 1s gap – ISO 8201 Temporal Any T 1 T 8
T 12 /system/1/assets/files/000/000/945/945/689d9405a/original/TF058.wav 1000(0.5s on, 0.5s off)x3 + 1s gap – ISO 8201 Temporal Any T 1 T 8
T 13 /system/1/assets/files/000/000/950/950/2d337d14e/original/TF059.wav 422/775 – (0.85 on, 0.5 off) x3 + 1s gap – NFPA Temporal Any T 1 T 8
T 14 /system/1/assets/files/000/000/399/399/84b54dafb/original/TF034.WAV 1000/2000 @ 1Hz – Singapore Any T 3 T 35
T 15 /system/1/assets/files/000/000/393/393/744c6f53f/original/TF030.WAV 300 Continuous Any T 24 T 35
T 16 /system/1/assets/files/000/000/391/391/5f7a58b54/original/TF028.WAV 440 Continuous Any T 24 T 35
T 17 /system/1/assets/files/000/000/948/948/c697b364a/original/TF060.wav 470 Continuous Any T 24 T 35
T 18 /system/1/assets/files/000/000/949/949/7e429e658/original/TF061.wav 500 Continuous – IMO code 2 (Low) Any T 24 T 35
T 19 /system/1/assets/files/000/000/390/390/10abe0caa/original/TF027.WAV 554 Continuous Any T 24 T 35
T 20 /system/1/assets/files/000/000/384/384/5c30f9f4d/original/TF020.WAV 660 Continuous Any T 24 T 35
T 21 /system/1/assets/files/000/000/380/380/06feaa7b3/original/TF015.WAV 800 Continuous – IMO code 2 (High) Any T 24 T 35
T 22 /system/1/assets/files/000/000/406/406/49b88184e/original/TF043.WAV 1200 Continuous Any T 24 T 35
T 23 /system/1/assets/files/000/000/407/407/ecce63f4f/original/TF038.WAV 2000 Continuous Any T 3 T 35
T 24 /system/1/assets/files/000/000/421/421/b578af8a9/original/TF005.WAV 2400 Continuous Any T 20 T 35
T 25 /system/1/assets/files/000/000/951/951/d9ce2b2c6/original/TF062.wav 440 @ 0.83Hz (0.60s on, 0.60s off) Intermittent Any T 44 T 8
T 26 /system/1/assets/files/000/000/954/954/b703d99f1/original/TF063.wav 470 @ 0.9Hz (0.55s on, 0.55s off) Intermittent Any T 44 T 8
T 27 /system/1/assets/files/000/000/955/955/0f602886a/original/TF064.wav 470 @ 5Hz (0.10s on, 0.10s off) Intermittent Any T 44 T 8
T 28 /system/1/assets/files/000/000/956/956/dbb5f64db/original/TF065.wav 544 @ 1.14Hz (0.43s on, 0.44s off) Intermittent Any T 24 T 8
T 29 /system/1/assets/files/000/000/957/957/7bd3d8c1c/original/TF066.wav 655 @ 0.875Hz (0.57s on, 0.57s off) Intermittent Any T 44 T 8
T 30 /system/1/assets/files/000/000/397/397/d6d84d0c3/original/TF018.WAV 660 @ 0.28Hz (1.80s on, 1.80s off) Intermittent Any T 24 T 8
T 31 /system/1/assets/files/000/000/381/381/93f51c79a/original/TF016.WAV 660 @ 3.3Hz (0.15s on, 0.15s off) Intermittent Any T 24 T 8
T 32 /system/1/assets/files/000/000/410/410/a0f0ba2a6/original/TF033.WAV 745 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T 24 T 8
T 33 /system/1/assets/files/000/000/379/379/51c1bb5a9/original/TF014.WAV 800 (0.25s on, 1.00s off) Intermittent Any T 24 T 8
T 34 /system/1/assets/files/000/000/388/388/b4cf9203e/original/TF023.WAV 800 @ 2Hz (0.25s on, 0.25s off) – IMO code 3.a (High) Any T 24 T 8
T 35 /system/1/assets/files/000/000/377/377/ac5498db0/original/TF011.WAV 1000 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T 24 T 8
T 36 /system/1/assets/files/000/000/378/378/6380218ec/original/TF013.WAV 2400 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T 24 T 8
T 37 /system/1/assets/files/000/000/958/958/a90e62da4/original/TF067.wav 2900 @ 5Hz (0.10s on, 0.10s off) Intermittent Any T 24 T 8
T 38 /system/1/assets/files/000/000/959/959/f34b52faa/original/TF068.wav 363/518 @ 1Hz (0.50s / 0.50s) Alternating Any T 8 T 19
T 39 /system/1/assets/files/000/000/960/960/368703340/original/TF069.wav 450/500 @ 2Hz (0.25s / 0.25s) Alternating Any T 8 T 19
T 40 /system/1/assets/files/000/000/385/385/a85a0a356/original/TF021.WAV 554/440 @ 1Hz (0.50s / 0.50s) Alternating Any T 24 T 19
T 41 /system/1/assets/files/000/000/961/961/be2680966/original/TF070.wav 554/440 @ 0.65Hz (0.76s / 0.76s) Alternating Any T 8 T 19
T 42 /system/1/assets/files/000/000/962/962/314fe8a1b/original/TF071.wav 561/760 @ 0.83Hz (0.60s / 0.60s) Alternating Any T 8 T 19
T 43 /system/1/assets/files/000/000/963/963/5f6deb8a1/original/TF072.wav 780/600 @ 0.96Hz (0.52s / 0.52s) Alternating Any T 8 T 19
T 44 /system/1/assets/files/000/000/419/419/e353c86c4/original/TF002.WAV 800/1000 @ 2Hz (0.25s / 0.25s) Alternating Any T 24 T 19
T 45 /system/1/assets/files/000/000/419/419/e353c86c4/original/TF002.WAV 970/800 @ 2Hz (0.25s / 0.25s) Alternating Any T 8 T 19
T 46 /system/1/assets/files/000/000/375/375/771bd7a3e/original/TF012.WAV 800/1000 @ 0.875Hz (0.57s / 0.57s) Alternating Any T 24 T 19
T 47 /system/1/assets/files/000/000/374/374/021ee6540/original/TF010.WAV 2400/2900 @ 2Hz (0.25s / 0.25s) Alternating Any T 24 T 19
T 48 /system/1/assets/files/000/000/965/965/e3d76c24c/original/TF073.wav 500/1200 @ 0.3Hz (1.67s / 1.67s) Sweeping Any T 24 T 12
T 49 /system/1/assets/files/000/000/964/964/4e1cd3f7f/original/TF074.wav 560/1055 @ 0.18Hz (2.73s / 2.73s) Sweeping Any T 24 T 12
T 50 /system/1/assets/files/000/000/966/966/a8e5f4440/original/TF075.wav 560/1055 @ 3.3Hz (0.15s / 0.15s) Sweeping Any T 24 T 12
T 51 /system/1/assets/files/000/000/969/969/5734194b1/original/TF076.wav 600/1250 @ 0.125Hz (4s / 4s) Sweeping Any T 24 T 12
T 52 /system/1/assets/files/000/000/394/394/1bfee2f1b/original/TF031.WAV 660/1200 @ 1Hz (0.50s / 0.50s) Sweeping Any T 24 T 12
T 53 /system/1/assets/files/000/000/420/420/50f9ee7a7/original/TF004.WAV 800/1000 @ 1Hz (0.50s / 0.50s) Sweeping Any T 24 T 12
T 54 /system/1/assets/files/000/000/392/392/68d5d1294/original/TF029.WAV 800/1000 @ 7Hz (0.07s / 0.07s) Sweeping Any T 24 T 12
T 55 /system/1/assets/files/000/000/389/389/68683d240/original/TF024.WAV 800/1000 @ 50Hz (0.01s / 0.01s) Sweeping Any T 24 T 12
T 56 /system/1/assets/files/000/000/422/422/42b72dd93/original/TF006.WAV 2400/2900 @ 7Hz (0.07s / 0.07s) Sweeping Any T 24 T 12
T 57 /system/1/assets/files/000/000/373/373/a686b0abe/original/TF007.WAV 2400/2900 @ 1Hz (0.50s / 0.50s) Sweeping Any T 24 T 12
T 58 /system/1/assets/files/000/000/398/398/7c1bf5e00/original/TF025.WAV 2400/2900 @ 50Hz (0.01s / 0.01s) Sweeping Any T 24 T 12
T 59 /system/1/assets/files/000/000/967/967/2e92dbc46/original/TF077.wav 2500/3000 @ 2Hz (0.25s / 0.25s) Sweeping Any T 24 T 12
T 60 /system/1/assets/files/000/000/968/968/5dfcb9aea/original/TF078.wav 2500/3000 @ 7.7Hz (0.65s / 0.65s) Sweeping Any T 24 T 12
T 61 /system/1/assets/files/000/000/408/408/e0fadcdd2/original/TF042.WAV 800Hz Motor Siren Any T 24 T 12
T 62 /system/1/assets/files/000/000/404/404/1c1741943/original/TF041.WAV 1200Hz Motor Siren Any T 24 T 12
T 63 /system/1/assets/files/000/000/409/409/590aa5e82/original/TF044.WAV 2400Hz Motor Siren Any T 24 T 12
T 64 /system/1/assets/files/000/000/395/395/631e82dc8/original/TF026.WAV Simulated Bell Any T 21 T 12
For Stage 2 any Stage 1 alarm tone sound can be selected.
Country specific or custom tone configurations and alarm frequencies are available upon request.

Upcoming Events

Fse (4)
Cafaa%202020%20final%20cmyk
Logo
Nfpa conference expo