The flameproof BExH120-R ‘Belltronic’ Signalling Bell is suitable for Zone 1 & 2 applications. The BExH120D authentically reproduces the traditional sound of a electro-mechanical bell whilst providing a significantly higher level of performance and reliability. The
BExDH120-R variant is also suitable for Zone 21 & 22.
Datasheet | Datasheet.pdf |
Ex d Gas installation | IS2491-P-C__BExH120D_Gas_.pdf |
Ex d & Ex tD Gas & Dust installation | IS2490-P-A__BExDH120D_Gas-Dust_.pdf |
IECEx certificate | IECEx_KEM_10.0003X_Issue_2_BExS.pdf |
IECEx certificate | IECEx_KEM_10.0003_Issue_1.pdf |
ATEX certificate | DEKRA_99ATEX6312_Issue_4_BExS.pdf |
ATEX certificate | KEMA_99ATEX6312_Issue_3.pdf |
INMETRO certificate | 10-IEx-0009_Rev_1_BExS.pdf |
Russian Ex certificate | EAC_EU_C-GB.AA71.B.00273_20.pdf |
RTN permit | RTN_permit_PPC_00-29227.pdf |
Russian Maritime register | 19.00195.278.pdf |
Declaration of Conformity | DC-001_Issue_H_BExS__BExL.pdf |
2D drawing (PDF) | SK0114_Issue_B.pdf |
2D drawing (DWG) | SK0114_Issue_B.dwg |
Hi-res product image 1 (TIFF) | 1-22-080_BExH120D-R.tif |
Lo-res product image 1 (JPG) | 1-22-080_BExH120D-R.jpg |
Hi-res product image 2 (TIFF) | 1-22-080_BExH120D-R-R.tif |
Lo-res product image 2 (JPG) | 1-22-080_BExH120D-R-R.jpg |
Nominal output: | 106dB(A) @ 1m +/- 3dB [97dB(A) @ 10ft/3m] |
Volume control: | Yes |
Voltages DC: | 24vdc |
Voltages AC: | 115vac; 230vac |
Ingress protection: | IP66/67 |
Enclosure matl: | Marine grade copper free LM6 Aluminium |
Enclosure finish: | Chromate & powder coated – anti-corrosion |
Colour: | RAL3000 Red or RAL7038 Grey (others available on request) |
BExH120-R flare: | High impact UL94 V0 & 5VA FR ABS |
BExDH120-R flare: | Anti-Static High impact ABS (Black) |
Cable entries: | Dual M20 ISO (one stopping plug inc) |
Terminals: | 0.5 – 2.5mm² (20-14 AWG) |
Enclosure volume: | <2 litres |
Line monitoring: | Blocking diode included EOL Min. 500 Ohm 2w, or 3k3 Ohm 0.5w resistor or diode (DC versions) can be fitted |
Weight : | DC: 3.20kg/7.04Ibs AC: 3.40kg/7.48Ibs |
Voltage: | Current: | |
---|---|---|
24V dc | 400mA | |
115V ac | 50/60Hz | 130mA |
230V ac | 50/60Hz | 65mA |
Part Code: | Classification: |
---|---|
BExH120DR**-G Grey Housing & Red Gong |
ATEX / IECEx: II 2G Ex d IIB T4 Ta. -50 to +70°C II 2G Ex d IIC T4 Ta. -50 to +55°C |
BExH120DR**-R Red Housing & Red Gong |
ATEX / IECEx: II 2G Ex d IIB T4 Ta. -50 to +70°C II 2G Ex d IIC T4 Ta. -50 to +55°C |
BExDH120DR**-G Grey Housing & Black Gong |
ATEX / IECEx: II 2G Ex d IIB T4 Ta. -50° to +70°C II 2G Ex d IIC T4 Ta. -50° to +55°C II 2D Ex tD A21 IP67 T115 based on a max. Ta. of 70°C |
BExDH120DR**-R Red Housing & Black Gong |
ATEX / IECEx: II 2G Ex d IIB T4 Ta. -50° to +70°C II 2G Ex d IIC T4 Ta. -50° to +55°C II 2D Ex tD A21 IP67 T115 based on a max. Ta. of 70°C |
** = Voltage reference: | |
Options: | 24DC, 115AC, 230AC |
Stage 1 | WAV file | Frequency Description. | Stg 2 | Stg 3 |
---|---|---|---|---|
T 1 | /system/1/assets/files/000/000/411/411/491442314/original/TF046.WAV | Industrial Hooter | T 3 | T 5 |
T 2 | /system/1/assets/files/000/000/414/414/146644246/original/TF047.WAV | High Frequency Mechanical Siren | T 1 | T 5 |
T 3 | /system/1/assets/files/000/000/416/416/0c52c2259/original/TF048.WAV | Medium Frequency Mechanical Siren | T 1 | T 5 |
T 4 | /system/1/assets/files/000/000/413/413/c47bf00c7/original/TF049.WAV | Electro Mechanical Buzzer | T 2 | T 5 |
T 5 | /system/1/assets/files/000/000/423/423/854c33e83/original/TF050.WAV | Mechanical Bell | T 1 | T 2 |
Country specific or custom tone configurations and alarm frequencies are available upon request. |