Product finder
Product code
Application
Environment
Device
Category
Product
Type
Product finder

Find the right E2S product

Search

STExB2X10 Xenon Strobe Beacon 1-21-170

Product Image
Product Image
Product Image
The STExB2X10 is a globally approved explosion proof 10 Joule Xenon beacon. The robust corrosion proof 316L stainless steel enclosure ensures suitability for all Zone 1, 2, 21 & 22 and Class I Div 2 hazardous location signalling applications.
Request a quote for this product
Type
Voltage
Cable entries
Stopping plug/adaptor material
Guard material
Product version
Product option
Enclosure colour
Lens Color
Part Number:
STExB2
Request Price or enquire about this product
Enquire about
Xenon Strobe Beacon

Upgraded Product

  • New UL & cUL approval for Class I Zone 1 and Class I Division 2 applications
  • Lower in-rush electronics
  • SIL2 compliant version with monitoring
  • A4 316 stainless steel guard as standard

Description

The STExB2X10 beacons produce a high output Xenon flash required for effective signalling in environments with elevated levels of ambient light. The field replaceable colour filter enhances the strobe and is constructed from UV stable PC.
The stainless steel enclosure features a threaded flame path, four cable entries and a large termination area – all of which significantly reduce installation time. SIL1 & SIL2 Route 2H compliant to IEC61508 (2010) as standard, with optional diagnostic module for Route 1H SIL2 compliance. DNV type approved for exposed locations.

Downloads

Datasheet Datasheet.pdf
Install manual: Product version [A] D199-01-201-IS_Issue_5__STExB2X_.pdf
-Install manual Telephone-Relay version [T] D199-01-581-IS_Issue_2__STExB2-T_.pdf
Install manual Product version [M] D199-01-211-IS_Issue_1__STExB2X10-X15-M_.pdf
Install manual: Product version [S] D199-01-621-IS_Issue_2__STExB2-S_.pdf
Installation Manual - Russian D199-00-201-IS-RUS_Issue_3_STExB2X.pdf
INMETRO Installation Manual D199-00-201-IS-IEx_Issue_B_STExB2X.pdf
IECEx certificate IECEx_ULD_16.0017X_005_STEx.pdf
ATEX certificate DEMKO_16_ATEX_1466X_Rev._5_STEx.pdf
UL certificate of compliance UL_CoC-20211026-E245313_Vol2_Sec2_STEx.pdf
UKCA Certificate UL21UKEX2019X_Rev.2_STEx.pdf
INMETRO certificate IEx20.0156X_R1_STExS_L_B_C_J.pdf
Ex EAC TR CU 012/2011 Certificate RU_-GB.65..01252_21.pdf
DNV Type Approval TAA00001JN_2.pdf
ECAS Ex Approval 24-07-117236_E24-07-120642_NB0007_STEx.pdf
Ingress Protection certificate TL17013A_STExCP8_IP6X_STEx_IPX6.pdf
Ingress Protection certificate TL24103B_STExB2_IP67.pdf
Declaration of Conformity DC-070_Issue_H_STEx.pdf
Declaration of Conformity UKCA DC-100_Issue_A_STEx_UKCA.pdf
SIL Certificate: Product version [A] T900-123_4_SIL2_SIL1_2H__D1xB2_STExB2_GNExB_BExBG_.pdf
SIL Certificate: Product version [S] T727-041-3_SIL2_1H__BExBG_D1xB2_GNExB2_STExB2_.pdf
2D drawing (PDF) D199-05-201_Issue_2.pdf
2D drawing (DWG) D199-05-201_Issue_2.DWG
3D drawing (STEP) D199-05-201-3D_Issue_1_STExB2_.STEP
Wiring Schematic D199-06-201_Issue_C_STExB2X_.pdf
Wiring schematic: Product version [S] D191-06-621_Issue_1.pdf
Nameplate Drawing D199-09-201_Issue_2_STExB2X.pdf
Equipment Tag Drawing D254-00-101_Issue_1.pdf
Duty Label Drawing D254-00-001_Issue_1.pdf
Pole Mount & Sun Shade Drawing D217-05-281_Issue_1__STExB2_.pdf

Features

  • Four flash rates: 1Hz, 1.3Hz, 1.5Hz & double flash
  • Automatic synchronisation on multi-beacon systems
  • User replaceable Xenon tube secured against shock & vibration
  • A4 316 Stainless Steel guard included as standard
  • UV stable polycarbonate lens colour filter – field replaceable
  • 4 x cable entries
  • Stopping plugs included
  • Robust corrosion proof 316L stainless steel enclosure
  • DNV type approved IEC 60945 & DNVGL-CG-0339

Specification

Source: Xenon Strobe
Energy: 10 Joules (10Ws)
Flash rates: 1Hz flash (60 fpm)
1.3Hz flash (80 fpm)
1.5Hz flash (90 fpm)
Double flash (120 fpm)
Eff. Intensity cd: 479.39 cd – measured ref to I.E.S
Peak Candela: 110,243 cd – measured ref to I.E.S
Eff. Intensity cd: 500 cd – calculated from energy (J)
Peak Candela: 1,000,000 cd – calculated from energy (J)
Lens colours: Amber, Blue, Clear, Green, Magenta, Red & Yellow
Voltage DC: 24V dc (20-28Vdc), 48Vdc (42-54Vdc)
Voltage AC: 115Vac (110-120Vac), 230Vac (220-240Vac)
In-rush: 813mA within 6ms @ 24Vdc
Safety Integrity Level: Product version A: SIL1 and SIL2 Route 2H
Product version S: SIL2 Route 1H with diagnostics SFF: >99%
See install manual for reliability & functional safety data
Ingress protection: IP rating per EN60529:IP66/67
Type rating per UL50E/NEMA250:4/4X/3R/13
Lens material: High impact Borosilicate glass
Enclosure material: 316L Stainless Steel
Enclosure colour: Red
Enclosure finish: Chromate & powder coated finish
Cable entries: Side: 4 x M20x1.5mm
Stopping plugs included
Stopping plugs: Stainless Steel
Terminals: 0.5 – 2.5mm² (20-14 AWG)
Duplicated terminals
Line monitoring: Blocking diode included
EOL Min. 500 Ohm 2W, or 3k3 Ohm 0.5W resistor
or diode (DC versions) can be fitted
Ground/Earth stud: M5
Line monitoring: Blocking diode included
EOL Min. 500 Ohm 2w, or 3k3 Ohm 0.5w resistor
or diode (DC versions) can be fitted
Enclosure volume: <2 litres
Installation temp: -50° to +85°C (-58°F to +185°F)
Storage temp: -50° to +85°C (-58°F to +185°F)
Relative humidity: 99% – tropicalised/conformal coated electronics
MTBF DC: 198.88 years / 1,742,161 hours – MIL 217
MTBF AC: 253.68 years / 2,222,223 hours – MIL 217
Weight: 6.0kg/13.23lbs
*All candela data is representative of performance with clear lens at optimum voltage.

Current Consumption

Nominal
Voltage:
Voltage
range:
Nominal
current:
Max.
current:
In-rush:
24Vdc 20-28Vdc 605mA 710mA 753mA <6ms
48Vdc 42-54Vdc 230mA 250mA -
115Vac 110-120Vac 50/60Hz 220mA 300mA -
230Vac 220-240Vac 50/60Hz 130mA 180mA -

Part Codes

Part Code: Identifier: Description:
Product type: STExB2
Type: X10 Xenon Beacon – 10 Joule
Voltage: DC024
DC048
AC115
AC230
24Vdc (20-28Vdc)
48Vdc (42-54Vdc)
115Vac (110-120Vac)
230Vac (220-240Vac)
Cable entries:[e] A
B
C
D
E
F
G
H
I
J
4 x M20x1.5mm
2 × 1/2" NPT – adaptors
2 × 3/4" NPT – adaptors
2 x M25x1.5mm – adaptors
1 × 1/2" NPT – adaptor
1 × 3/4" NPT – adaptor
1 x M25x1.5mm – adaptor
3 × 1/2" NPT – adaptors
3 × 3/4" NPT – adaptors
3 x M25x1.5mm – adaptors
Stopping plug/
adaptor material: [m]
S Stainless Steel
Guard material:
[s]
1
3
5
A4 316 Stainless Steel
A4 316 St/St with Equip. Tag
A4 316 St/St with Equip. Tag and Duty Label
Product version: [v] A

M

S


T
UL, cUL, IECEx, ATEX, Ex EAC, INMETRO
SIL1 & SIL2 Route 2H
IECEx, ATEX, Ex EAC, INMETRO, DNV
SIL1 & 2 Route 2H
UL, cUL, IECEx, ATEX, Ex EAC, INMETRO
(24Vdc only)
SIL2 Route 1H with diagnostics SFF: >99%
IECEx, ATEX, Ex EAC, INMETRO – Telephone/Relay Initiate
Product option: [o] 1
X
Standard product
Custom configuration – contact E2S
Enclosure colour: [x] R
S
Red
Special colour – contact E2S
Lens colour: [y] A
B
C
G
M
R
Y
Amber
Blue
Clear
Green
Magenta
Red
Yellow
Accessories:
SP65-0001-A4
SP65-0003-A4

Pole Mount Bracket Kit St/St A4 (316)
Sunshade – St/St A4 (316)

Approvals

  • UL/cUL – File ref: E245313
  • IECEx Certificate: IECEx ULD 16.0017X
  • ATEX Certificate: DEMKO 16 ATEX 1466X
  • UKCA certificate: UL21UKEX2019X
  • TR-CU Ex EAC certificate: RU С-GB.НА65.В.01252_21
  • INMETRO IEx 20.0156X
  • DNV type approved: TAA00001JN
  • SIL1 & SIL2 compliant to IEC61508 (2010)

Assemblies

The STExB2X10 is available as a plated assembly configured with a STEx type alarm horn sounder and additional
STEx type Xenon strobe or LED beacons with or without a STExJ2 Ex d junction box. Contact E2S for further information.

Coding

  • IECEx / ATEX
    II 2G Ex db IIC T5 Gb Ta -50°C to +45°C (DC only)
    II 2G Ex db IIC T4 Gb Ta -50°C to +80°C (AC: +70°C)
    II 2G Ex db IIC T3 Gb Ta -50°C to +85°C (AC: +80°C)
    II 2D Ex tb IIIC T118°C Db Ta -50°C to +70°C (AC: T128°C)
  • NEC Class / Zone
    Class I Zone 1 AEx db IIC T4 Ta -50°C to +70°C
    Class I Zone 1 AEx db IIC T5 Ta -50°C to +45°C (DC only)
  • CEC Class / Zone
    Ex db IIC T4 Ta -50°C to +70°C
    Ex db IIC T5 Ta -50°C to +45°C (DC only)
  • NEC / CEC Class / Div
    Class I Div 2 Group ABCD T4 Ta -50°C to +70°C
    Class I Div 2 Group ABCD T5 Ta -50°C to +45°C (DC only)

Effective Candela lens colour factor

Amber Blue Clear Green Magenta Red Yellow
0.59 0.27 1.00 0.51 0.34 0.15 0.85

Upcoming Events

Fse (4)
Cafaa%202020%20final%20cmyk
Logo
Nfpa conference expo