IS-mA1 IS-minialarm 1-12-010

Product image
The IS-mA1 is a compact, 100dB(A) alarm sounder. Approvals include ATEX, IECEx and EAC Ex for Zone 0 applications and FM approval for Class I Division 1 and Class I Zone 0 applications.
Request a quote for this product
Version
Part Number:
IS-mA1
Request Price or enquire about this product
Enquire about
IS-minialarm

Product Upgrade

  • The IS-mA1M version alarm horn sounder, approved for Group I mining applications, is now certified to IECEx standards.
  • Coding: Group I M1 Ex ia I Ma
  • IECEx certificate: IECEx SIR 06.0045X
    Contact E2S sales for further information.

Description

The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.
The IS-mA1M version is also available for Group I mining environments.

Downloads

Datasheet Datasheet.pdf
Datasheet Drawing 1-12-010IS-mA1_CAT.tif
Installation Manual D251-01-001-IS_Issue_1__IS-mA1_.pdf
ANZEx installation IS5011_A_IS-mA1AN.pdf
Mining Version Installation D251-01-051-IS_Issue_1__IS-mA1M_.pdf
IECEx certificate IECEx_SIR_06.0045X_Issue_4_IS-mini_range.pdf
ATEX certificate Sira_05ATEX2084X_Issue_9_IS-mini_range.pdf
FM certificate FM_CoC_3029125_IS-mini.pdf
VdS certificate VdS_G207130_IS-mA1_2019-06-10.pdf
UKCA Certificate CSAE_21UKEX2553X_Iss_0_IS-Mini.pdf
EC CPR Certificate 0786-CPD-20338_IS-mA1.pdf
Russian Ex certificate EAC_EU_C-GB.AA71.B.00273_20.pdf
RTN permit RTN_permit_PPC_00-29227.pdf
Russian Fire certificate Russian_Fire_Certificate_-GB.25..03286.PDF
Russian Maritime register 19.00195.278.pdf
ANZEx certificate ANZEx_07.4044X_Issue_0_IS-mini_Range.pdf
Declaration of Conformity DC-011_Issue_J_IS-Mini.pdf
Declaration of Conformity UKCA DC-088_Issue_A_UKCA_IS-Mini.pdf
Declaration of Performance DP_-_0786-CPD-20338-Issue_A_IS-mA1.pdf
2D drawing (PDF) D251-05-001_Issue_1.pdf
2D drawing (DWG) D251-05-001_Issue_1.dwg
3D drawing (STEP) D251-05-001-3D_Issue_1.STEP
Wiring Schematic D5035_Issue_A_IS-mA1.pdf
Nameplate Drawing D251-09-001_Issue_1_IS-mA1.pdf
Nameplate Drawing D251-09-051_Issue_1_IS-mA1M.pdf
Hi-res product image 1 (TIFF) 1-12-010_IS-mA1-R.tif

Features

  • Input overload and reverse current protection
  • End of line resistor certified
  • Auto synchronised sound output
  • Available with custom tone configurations

Specification

Nominal output: 100dB(A) @ 1m +/- 3dB – Tone 2*[91dB(A) @ 10ft/3m]
No. of tones: 49 (UKOOA/PFEER compliant)
No. of stages: 3
Volume control: Max. 100dB(A); Min. 90dB(A) – Tone 2
Effective range: 40m/131ft @ 1KHz
Voltage: 16-28vdc via Zener barrier or galvanic isolator
Current: 25mA typical when powered from 24v supply via 28v 300 Ohm Zener barrier
Ingress protection: IP65
Rating: Continuous
Enclosure material: UL94V0 & 5VA FR ABS
Enclosure colour: RAL3000 Red
Fixings: Stainless Steel
Cable entries: 2 x M20 clearance gland knockouts. Custom configurations also available.
MTBF: 273.1 years / 2,392,344 hours – MIL 217
Terminals: 0.5 to 2.5mm²
Operating temp: -40° to +60°C [-40 to +140°F]
Storage temp: -40° to +70°C [-40 to +158°F]
Relative humidity: 90% at 20°C [68°F]
Weight: 0.36Kg / 0.79Ibs

Part Codes

IS-mA1-R
ATEX / IECEx / FM
II 1G Ex ia IIC T4 Ga (-40ºC <=Ta<= +60°C)
IS Class I, Zone 0, AEx ia IIC T4
IS Class l, Division 1, Groups A, B, C, D
EAC Ex
0ExiaIICT4 IP65 -40° to +60°C
IS-mA1M-R
IECEx & ATEX
Group I M1 Ex ia I Ma (-40ºC <=Ta<= +60°C)
May be powered from any certified Zener barrier or galvanic isolator
whose output parameters do not exceed:
Uo: 28VDC Io: 93mA Po: 660mW

Approvals

  • ATEX certificate: SIRA 05ATEX2084X
  • IECEx certificate: IECEx SIR 06.0045X
  • FM approved
  • EAC Ex certificate: POCC GB.JB05.B03365

Tone Table

Stage 1 WAV file Frequency Description. Stg 2 Stg 3
T 1 340 Hz Continuous T 2 T 5
T 2 800/1000Hz @ 0.25 sec Alternating T 17 T 5
T 3 500/1200Hz @ 0.3Hz 0.5 sec Slow Whoop T 2 T 5
T 4 800/1000Hz @ 1Hz Sweeping T 6 T 5
T 5 2400Hz Continuous T 3 T 20
T 6 2400/2900Hz @ 7Hz Sweeping T 7 T 5
T 7 2400/2900Hz @ 1Hz Sweeping T 10 T 5
T 8 500/1200/500Hz @ 0.3Hz Sweeping T 2 T 5
T 9 1200/500Hz @ 1Hz – DIN / PFEER P.T.A.P. T 15 T 2
T 10 2400/2900Hz @ 2Hz Alternating T 7 T 5
T 11 1000Hz @ 1Hz Intermittent T 2 T 5
T 12 800/1000Hz @ 0.875Hz Alternating T 4 T 5
T 13 2400Hz @ 1Hz Intermittent T 15 T 5
T 14 800Hz 0.25sec on, 1 sec off Intermittent T 4 T 5
T 15 800Hz Continuous T 2 T 5
T 16 660Hz 150mS on, 150mS off Intermittent T 18 T 5
T 17 544Hz (100mS)/440Hz (400mS) – NF S 32-001 T 2 T 27
T 18 660Hz 1.8sec on, 1.8sec off Intermittent T 2 T 5
T 19 1.4KHz-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s -NFC48-265 T 2 T 5
T 20 660Hz Continuous T 2 T 5
T 21 554Hz/440Hz @ 1Hz Alternating T 2 T 5
T 22 544Hz @ 0.875 sec. Intermittent T 2 T 5
T 23 800Hz @ 2Hz Intermittent T 6 T 5
T 24 800/1000Hz @ 50Hz Sweeping T 29 T 5
T 25 2400/2900Hz @ 50Hz Sweeping T 29 T 5
T 26 Bell T 2 T 15
T 27 554Hz Continuous T 26 T 5
T 28 440Hz Continuous T 2 T 5
T 29 800/1000Hz @ 7Hz Sweeping T 7 T 5
T 30 300Hz Continuous T 2 T 5
T 31 660/1200Hz @ 1Hz Sweeping T 26 T 5
T 32 Two T chime. T 26 T 15
T 33 745Hz @ 1Hz Intermittent T 2 T 5
T 34 1000 & 2000Hz @ 0.5 sec Alternating – Singapore T 38 T 45
T 35 420Hz @ 0.625 sec Australian Alert T 36 T 5
T 36 500-1200Hz 3.75sec /0.25sec. Australian Evac. T 35 T 5
T 37 1000Hz Continuous – PFEER Toxic Gas T 9 T 45
T 38 2000Hz Continuous T 34 T 45
T 39 800Hz 0.25sec on, 1 sec off Intermittent T 23 T 17
T 40 544Hz (100mS)/440Hz (400mS) – NF S 32-001 T 31 T 27
T 41 Motor Siren – slow rise to 1200 Hz T 2 T 5
T 42 Motor Siren – slow rise to 800 Hz T 2 T 5
T 43 1200 Hz Continuous T 2 T 5
T 44 Motor Siren – slow rise to 2400 Hz T 2 T 5
T 45 1KHz 1s on, 1s off Intermittent – PFEER Gen. Alarm T 38 T 34
T 46 1200/500Hz @ 1Hz – DIN / PFEER P.T.A.P. T 47 T 37
T 47 1KHz 1s on, 1s off Intermittent – PFEER Gen. Alarm T 46 T 37
T 48 420Hz @ 0.625 sec Australian Alert T 49 T 5
T 49 500-1200Hz 3.75sec /0.25sec. Australian Evac. T 26 T 37
Country specific or custom tone configurations and alarm frequencies are available upon request.