E2xS2F Alarm Sounder/Horn 1-32-020

Product image
Product Image
The hazardous area E2xS2F alarm horn sounder is UL/cULs approved for Class I Div 2 and Class II Div 2 as well as IECEx and ATEX certified for Zone 2 and 22 applications.
Request a quote for this product
Horn Type
Voltage
Cable Entry Type
Stopping plug/adaptor material
Bracket Material
Version
Enclosure Color
Part Number:
E2xS2
Request Price or enquire about this product
Enquire about
Alarm Sounder/Horn

Description

With a maximum sound level output of 121dB(A) at 1 metre and a choice of 45 alarm tones and 3 remotely
selectable stages the E2xS2F alarm sounder horn is suitable for all signalling applications with high ambient noise levels.
The E2x range features enclosures manufactured from lightweight, corrosion proof GRP and high impact, fire retardant ABS re-entrant flare horns; both of which are suitable for the harshest of environments.

Downloads

Datasheet Datasheet.pdf
Installation Manual D209-01-011-IS_Issue_4__E2xS2F_S2R_.pdf
IECEx certificate IECEx_ULD_14.0012X_Issue_2_E2x.pdf
ATEX certificate DEMKO_06ATEX_0421554X_Rev_2_E2x.pdf
UL certificate of compliance UL_CoC_-_20060331-E230764_Vol.1_Sec.1_E2xS__E2xC.pdf
UKCA Certificate UL21UKEX2135X_Rev._0_E2x.pdf
Russian Ex certificate C_RU_C-GB.71..00273_20.pdf
Declaration of Conformity DC-062_Issue_I_E2x.pdf
Declaration of Conformity UKCA DC-103_Issue_A_E2x_UKCA.pdf
2D drawing (PDF) D209-05-011_Issue_2.pdf
2D drawing (DWG) D209-05-011_Issue_2.dwg
3D drawing (STEP) D209-05-011-3D_Issue_1_.STEP
Wiring Schematic D209-06-001_Issue_B.pdf
Nameplate Drawing D209-09-011_Issue_2.pdf
Equipment Tag Drawing D254-00-101_Issue_1.pdf
Duty Label Drawing D254-00-001_Issue_1.pdf

Features

  • Automatic synchronisation on multi-sounder system.
  • Continuously rated.
  • Large termination area.
  • Stainless steel fixings.
  • Ratchet adjustable stainless steel ‘U’ bracket for 360° positioning.
  • Duplicate cable terminations (in & out for daisy-chain installations).
  • Tropicalisation available on request.
  • Available with custom tone configurations and frequencies.

Specification

Maximum output: 121dB(A) @ 1 metre [112dB(A) @ 10ft/3m]
Nominal output: 117dB(A) @ 1m +/- 3dB – Tone 2 [108dB(A) @ 10ft/3m]
No. of tones: 45 (UKOOA/PFEER compliant)
No. of stages: 3
Volume control: Max. 117dB(A); Min. 111dB(A)
- Tone 2
Effective range: 200m/656ft @ 1KHz
Voltages DC: 24Vdc (10-30Vdc); 48Vdc
Voltages AC: 115Vac; 230Vac
Ingress protection: IP rating per EN60079-0:IP64
IP rating per EN60529:IP66
Type rating per UL50E/NEMA250:4/4X/13
Enclosure material: UL94V0 GRP (PPS) & ABS
Cable entries: Dual M20x1.5 or 1/2"NPT
Terminals: 0.5 – 2.5mm² (20-14 AWG)
Line monitoring: Blocking diode included
EOL can be factory fitted
Operating temp: -20 to +55°C [-4° to +131°F]
Storage temp: -40 to +70°C [-40° to +158°F]
Relative humidity: 90% at 20°C [68°F]
Weight: DC: 2.75kg/6.05Ibs AC: 3.25kg/7.15Ibs
*SPL data +/-3dB(A). Measured at optimum voltage.

Current Consumption

Version: Voltage: Current:
24V dc 10-30vdc 280mA
48V dc 38-58vdc 215mA
115V ac 50/60Hz +/-10% 155mA
230V ac50/60Hz +/-10% 76mA

Part Codes

Part Code: Ident.: Description:
Product type: E2xS2 E2xS2 alarm hrn sounder
Flare type: F Flare Horn
Voltage: AC115
AC230
DC024
DC048
115V ac 50/60Hz
230V ac 50/60Hz
24V dc (10-30V dc)
48V dc
Cable entries: A
B
C
M20x1.5 & ½” NPT
M20x1.5 & M20x1.5
½” NPT & ½” NPT
Stopping plug material: N Nylon
Bracket & tag: [s] 1
2
3
4
304 A2 Stainless Steel
316 A4 Stainless Steel
304 A2 Stainless Steel & Equip. Tag
316 A4 Stainless Steel & Equip. Tag
Approvals: A1 UL, cULs, IECEx & ATEX
Enclosure: B Black
Accessories: SP65-0001-A4
SP65-0003-A4
Pole Mount Bracket Kit St/St A4 (316)
Sunshade – St/St A4 (316)

Approvals

  • ATEX certificate: DEMKO 06 ATEX 0421554X
  • IECEx certificate: IECEx ULD 14.0012X
  • UL/cUL File ref: E230764
  • UKCA certificate: UL21UKEX2135X
  • Ex EAC certified: EAC RU C-GB.AA71.B.00273/20

Coding

  • IECEx / ATEX:
    II 3G Ex ec IIC T4 Gc Ta -20°C to +55°C
    II 3D Ex tc IIIC T85°C Dc Ta -20°C to +55°C
  • NEC Class / Zone ratings US:
    Class I Zone 2 AEx ec IIC T4 Gc Ta -20°C to +55°C
    Zone 22 AEx tc IIIB T85°C Dc Ta -20°C to +55°C
  • CEC Class / Zone ratings Canada
    Class I Zone 2 Ex ec IIC T4 Gc X Ta -20°C to +55°C
    Zone 22 Ex tc IIIC T85°C Dc Ta -20°C to +55°C
  • NEC & CEC Class / Division Ratings for US / Canada
    Class I Div 2 Group ABCD T3C Ta -20°C to +55°C
    Class I Div 2 Group ABCD T4 Ta -20°C to +40°C
    Class II Div 2 Group FG T6 Ta -20°C to +55°C
    Class III Div 1 & 2 Ta -20°C to +55°C

Tone Table

Stage 1 WAV file Frequency Description. Stage 2 Stage 3
T 1 340 Hz Continuous T 2 T 5
T 2 800/1000Hz @ 0.25 sec Alternating T 17 T 5
T 3 500/1200Hz @ 0.3Hz 0.5 sec Slow Whoop T 2 T 5
T 4 800/1000Hz @ 1Hz Sweeping T 6 T 5
T 5 2400Hz Continuous T 3 T 20
T 6 2400/2900Hz @ 7Hz Sweeping T 7 T 5
T 7 2400/2900Hz @ 1Hz Sweeping T 10 T 5
T 8 500/1200/500Hz @ 0.3Hz Sweeping T 2 T 5
T 9 1200/500Hz @ 1Hz – DIN / PFEER P.T.A.P. T 15 T 2
T 10 2400/2900Hz @ 2Hz Alternating T 7 T 5
T 11 1000Hz @ 1Hz Intermittent T 2 T 5
T 12 800/1000Hz @ 0.875Hz Alternating T 4 T 5
T 13 2400Hz @ 1Hz Intermittent T 15 T 5
T 14 800Hz 0.25sec on, 1 sec off Intermittent T 4 T 5
T 15 800Hz Continuous T 2 T 5
T 16 660Hz 150mS on, 150mS off Intermittent T 18 T 5
T 17 544Hz (100mS)/440Hz (400mS) – NF S 32-001 T 2 T 27
T 18 660Hz 1.8sec on, 1.8sec off Intermittent T 2 T 5
T 19 1.4KHz-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s -NFC48-265 T 2 T 5
T 20 660Hz Continuous T 2 T 5
T 21 554Hz/440Hz @ 1Hz Alternating T 2 T 5
T 22 544Hz @ 0.875 sec. Intermittent T 2 T 5
T 23 800Hz @ 2Hz Intermittent T 6 T 5
T 24 800/1000Hz @ 50Hz Sweeping T 29 T 5
T 25 2400/2900Hz @ 50Hz Sweeping T 29 T 5
T 26 Bell T 2 T 15
T 27 554Hz Continuous T 26 T 5
T 28 440Hz Continuous T 2 T 5
T 29 800/1000Hz @ 7Hz Sweeping T 7 T 5
T 30 300Hz Continuous T 2 T 5
T 31 660/1200Hz @ 1Hz Sweeping T 26 T 5
T 32 Two T chime. T 26 T 15
T 33 745Hz @ 1Hz Intermittent T 2 T 5
T 34 1000 & 2000Hz @ 0.5 sec Alternating – Singapore T 38 T 45
T 35 420Hz @ 0.625 sec Australian Alert T 36 T 5
T 36 500-1200Hz 3.75sec /0.25sec. Australian Evac. T 35 T 5
T 37 1000Hz Continuous – PFEER Toxic Gas T 9 T 45
T 38 2000Hz Continuous T 34 T 45
T 39 800Hz 0.25sec on, 1 sec off Intermittent T 23 T 17
T 40 544Hz (100mS)/440Hz (400mS) – NF S 32-001 T 31 T 27
T 41 Motor Siren – slow rise to 1200 Hz T 2 T 5
T 42 Motor Siren – slow rise to 800 Hz T 2 T 5
T 43 1200 Hz Continuous T 2 T 5
T 44 Motor Siren – slow rise to 2400 Hz T 2 T 5
T 45 1KHz 1s on, 1s off Intermittent – PFEER Gen. Alarm T 38 T 34
Country specific or custom tone configurations and alarm frequencies are available upon request.

Upcoming Events

Fse (4)
Cafaa%202020%20final%20cmyk
Logo
Nfpa conference expo