E2xC1X05F Combination Alarm Horn & Xenon Beacon 1-34-010

Product image
Product Image
Product Image
The hazardous location E2xC1X05F combined alarm sounder and Xenon strobe beacon is UL/cULs approved for Class I Div 2 and Class II Div 2 as well as IECEx and ATEX certified for Zone 2 and 22 applications.
Request a quote for this product
Horn Type
Voltage
Cable Entry Type
Stopping plug/adaptor material
Bracket & Guard
Version
Enclosure Color
Lens Color
Part Number:
E2xC1X05
Request Price or enquire about this product
Enquire about
Combination Alarm Horn & Xenon Beacon

Description

The E2xC1X05F combines a 116dB(A) alarm sounder with a 5 Joule Xenon strobe beacon providing a complete audio-visual signalling solution whilst reducing the installation time and costs associated with multiple unit installations.
The E2x range features enclosures manufactured from lightweight, corrosion proof PPS and high impact, fire retardant ABS re-entrant flare horns; both of which are suitable for the harshest of environments.

Downloads

Datasheet Datasheet.pdf
Installation Manual D209-01-501-IS_Issue_3__E2xC1X05F_R_.pdf
IECEx certificate IECEx_ULD_14.0012X_Issue_2_E2x.pdf
ATEX certificate - GNExS1F/S1R/S2F DEMKO_06ATEX_0421554X_Rev_2_E2x.pdf
UL certificate of compliance UL_CoC_-_20060331-E230764_Vol.1_Sec.1_E2xS__E2xC.pdf
Russian Ex certificate C_RU_C-GB.71..00273_20.pdf
Declaration of Conformity DC-062_Issue_I_E2x.pdf
Declaration of Conformity UKCA DC-103_Issue_A_E2x_UKCA.pdf
2D drawing (PDF) D209-05-501_Issue_2.pdf
2D drawing (DWG) D209-05-501_Issue_2.dwg
3D drawing (STEP) D209-05-501-3D_Issue_1.STEP
Wiring Schematic D209-06-501_Issue_B.pdf
Nameplate Drawing D209-09-501_Issue_2.pdf
Equipment Tag Drawing D254-00-101_Issue_1.pdf
Duty Label Drawing D254-00-001_Issue_1.pdf

Features

  • Ratchet adjustable stainless steel ‘U’ bracket.
  • Stainless Steel dome guard as standard
  • Xenon tube mechanically secured against vibration/shock.
  • Automatic synchronisation on multi-sounder system.
  • Duplicate cable terminations.
  • Tropicalisation available on request.
  • Available with custom tone configurations and frequencies.

Specification

Alarm Horn Sounder:
Maximum output: 116dB(A) @ 1 metre [107dB(A) @ 10ft/3m]
Nominal output: 113dB(A) @ 1m +/- 3dB – Tone 2 [104dB(A) @ 10ft/3m]
No. of tones: 45 (UKOOA/PFEER compliant)
No. of stages: 3
Volume control: Max. 113dB(A) Min. 105dB(A) – Tone 2
Effective range: 100m/328ft @ 1KHz
Xenon Strobe Beacon:
Energy: 5 Joules (5Ws)
Flash rate: 1Hz (60 fpm)
Peak Candela: 500,000 cd – calculated from energy (J)
Effect. Intensity cd: 250 cd – calculated from energy (J)
Peak Candela: 34,122 cd* – measured ref. to I.E.S.
Effective Intensity cd: 108 cd* – measured ref. to I.E.S.
Lens colours: Amber, Blue, Clear, Green,
Magenta, Red & Yellow
General:
Voltages: 24Vdc; 48Vdc; 115Vac; 230Vac
Ingress protection: IP rating per EN60079-0:IP64
IP rating per EN60529:IP66
Type rating per UL50E/NEMA250:4/4X/13
Enclosure material: UL94V0 GRP (PPS) & ABS
Lens material: Borosilicate glass dome with PC prismatic lens cover.
Guard: Stainless Steel dome guard as standard
Cable entries: Dual M20x1.5 or 1/2"NPT
Terminals: 0.5 – 2.5mm² (20-14 AWG)
Line monitoring: Blocking diode included
EOL can be factory fitted
Operating temp: -20 to +55°C [-4° to +131°F]
Storage temp: -40 to +70°C [-40° to +158°F]
Relative humidity: 90% at 20°C [68°F]
Weight: DC: 3.00Kg/6.6Ibs AC: 3.50kg/7.7Ibs
* All candela data is representative of performance with clear lens at optimum voltage.

Current Consumption

Alarm Sounder Xenon Beacon
Version: Voltage: Current: Voltage: Current:
24Vdc 10-30Vdc 284mA 20-28Vdc 275mA
48Vdc 38-58Vdc 146mA 42-58Vdc 145mA
115Vac
50/60Hz
+/-10% 104mA +/-10% 80mA
230Vac
50/60Hz
+/-10% 54mA +/-10% 30mA

Part Codes

Part Code: Ident.: Description:
Product type: E2xC1X05 Combined alarm horn & Xenon
Type: F Flare re-entrant horn
Voltage: AC115
AC230
DC024
DC048
115Vac 50/60Hz
230Vac 50/60Hz
24Vdc (20-28Vdc)
48Vdc (42-54Vdc)
Cable entries:[e] A
B
C
M20x1.5 & ½” NPT
M20x1.5 & M20x1.5
½” NPT & ½” NPT
Stopping plug material: [m] N Nylon
Bracket & Guard & tag: [s] 1
2
3
4
304 A2 Stainless Steel
316 A4 Stainless Steel
304 A2 Stainless Steel & Equip. Tag
316 A4 Stainless Steel & Equip. Tag
Version: [v] A1 UL, cULs, IECEx & ATEX
Enclosure: [x] B Black
Lens colour: [y] A, B, C
G, M, R
Y
Amber, Blue, Clear
Green, Magenta, Red
Yellow
Accessories: SP65-0001-A4
SP65-0003-A4
Pole Mount Bracket Kit St/St A4 (316)
Sunshade – St/St A4 (316)

Approvals

  • ATEX certificate: DEMKO 06 ATEX 0421554X,
  • IECEx certificate: IECEx ULD 14.0012X
  • UL/cUL File ref: E230764
  • UKCA certificate: UL21UKEX2135X
  • Ex EAC certified: EAC RU C-GB.AA71.B.00273/20

Coding

  • IECEx / ATEX:
    II 3G Ex ec IIC T3 Gc Ta -20°C to +40°C
    II 3G Ex ec IIC T2 Gc Ta -20°C to +55°C
    II 3D Ex tc IIIC T85°C Dc Ta -20°C to +40°C
    II 3D Ex tc IIIC T100°C Dc Ta -20°C to +55°C
  • NEC Class / Zone ratings US:
    Class I Zone 2 AEx ec IIC T3 Gc Ta -20°C to +40°C
    Class I Zone 2 AEx ec IIC T2 Gc Ta -20°C to +55°C
    Zone 22 AEx tc IIIB T85°C Dc Ta -20°C to +40°C
    Zone 22 AEx tc IIIB T00°C Dc Ta -20°C to +55°C
  • CEC Class / Zone ratings Canada
    Class I Zone 2 Ex ec IIC T3 Gc X Ta -20°C to +40°C
    Class I Zone 2 Ex ec IIC T2 Gc X Ta -20°C to +55°C
    Zone 22 Ex tc IIIC T85°C Dc Ta -20°C to +40°C
    Zone 22 Ex tc IIIC T100°C Dc Ta -20°C to +55°C
  • NEC & CEC Class / Division Ratings for US / Canada
    Class I Div 2 Group ABCD T2D Ta -20°C to +55°C
    Class I Div 2 Group ABCD T3 Ta -20°C to +40°C
    Class II Div 2 Group FG T5 Ta -20°C to +55°C
    Class II Div 2 Group FG T6 Ta -20°C to +40°C
    Class III Div 1 & 2 Ta -20°C to +55°C

Tone Table

Stage 1 WAV file Frequency Description. Stage 2 Stage 3
T 1 340 Hz Continuous T 2 T 5
T 2 800/1000Hz @ 0.25 sec Alternating T 17 T 5
T 3 500/1200Hz @ 0.3Hz 0.5 sec Slow Whoop T 2 T 5
T 4 800/1000Hz @ 1Hz Sweeping T 6 T 5
T 5 2400Hz Continuous T 3 T 20
T 6 2400/2900Hz @ 7Hz Sweeping T 7 T 5
T 7 2400/2900Hz @ 1Hz Sweeping T 10 T 5
T 8 500/1200/500Hz @ 0.3Hz Sweeping T 2 T 5
T 9 1200/500Hz @ 1Hz – DIN / PFEER P.T.A.P. T 15 T 2
T 10 2400/2900Hz @ 2Hz Alternating T 7 T 5
T 11 1000Hz @ 1Hz Intermittent T 2 T 5
T 12 800/1000Hz @ 0.875Hz Alternating T 4 T 5
T 13 2400Hz @ 1Hz Intermittent T 15 T 5
T 14 800Hz 0.25sec on, 1 sec off Intermittent T 4 T 5
T 15 800Hz Continuous T 2 T 5
T 16 660Hz 150mS on, 150mS off Intermittent T 18 T 5
T 17 544Hz (100mS)/440Hz (400mS) – NF S 32-001 T 2 T 27
T 18 660Hz 1.8sec on, 1.8sec off Intermittent T 2 T 5
T 19 1.4KHz-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s -NFC48-265 T 2 T 5
T 20 660Hz Continuous T 2 T 5
T 21 554Hz/440Hz @ 1Hz Alternating T 2 T 5
T 22 544Hz @ 0.875 sec. Intermittent T 2 T 5
T 23 800Hz @ 2Hz Intermittent T 6 T 5
T 24 800/1000Hz @ 50Hz Sweeping T 29 T 5
T 25 2400/2900Hz @ 50Hz Sweeping T 29 T 5
T 26 Bell T 2 T 15
T 27 554Hz Continuous T 26 T 5
T 28 440Hz Continuous T 2 T 5
T 29 800/1000Hz @ 7Hz Sweeping T 7 T 5
T 30 300Hz Continuous T 2 T 5
T 31 660/1200Hz @ 1Hz Sweeping T 26 T 5
T 32 Two T chime. T 26 T 15
T 33 745Hz @ 1Hz Intermittent T 2 T 5
T 34 1000 & 2000Hz @ 0.5 sec Alternating – Singapore T 38 T 45
T 35 420Hz @ 0.625 sec Australian Alert T 36 T 5
T 36 500-1200Hz 3.75sec /0.25sec. Australian Evac. T 35 T 5
T 37 1000Hz Continuous – PFEER Toxic Gas T 9 T 45
T 38 2000Hz Continuous T 34 T 45
T 39 800Hz 0.25sec on, 1 sec off Intermittent T 23 T 17
T 40 544Hz (100mS)/440Hz (400mS) – NF S 32-001 T 31 T 27
T 41 Motor Siren – slow rise to 1200 Hz T 2 T 5
T 42 Motor Siren – slow rise to 800 Hz T 2 T 5
T 43 1200 Hz Continuous T 2 T 5
T 44 Motor Siren – slow rise to 2400 Hz T 2 T 5
T 45 1KHz 1s on, 1s off Intermittent – PFEER Gen. Alarm T 38 T 34
Country specific or custom tone configurations and alarm frequencies are available upon request.