AB105STR Alarm Horn Sounder & Xenon Strobe 2-31-160

Product image
Product Image
Product Image
The AB105STR combines a compact high output 113dB(A) alarm sounder with a powerful 5J Xenon strobe warning beacon. Featuring 64 alarm tone frequencies and 4 remotely activated stages/channels.
Request a quote for this product
Voltage
Back box/cable entries
Stopping plug material
Equip. tag/Duty label
Product version
Product option
Enclosure
Lens colour
Part Number:
AB105STR
Request Price or enquire about this product
Enquire about
Alarm Horn Sounder & Xenon Strobe

Upgraded Product:

  • New enhanced version
  • 64 alarm tones
  • 4 remotely activated alarm stages
  • Low in-rush electronics
  • Auto-synchronised horn and beacon
  • Pluggable, duplicated cable terminals
  • Dual cable entries with stopping plugs

Description

The low current consumption and high SPL in a robust fire retardant enclosure ensure the AB105STR is suitable for all general signalling applications. The alarm horn sounder & strobe beacon may be connected for simultaneous or independent operation. The Xenon beacon component features an automatically synchronised flash rate of 1Hz. The DC voltage versions also have user selectable 1.5Hz (90 flashes per minute) and double-strike flash rates. The double strike flash rate can be remotely activated via a third wire (as can alternative alarm tones on the horn sounder) enabling a audible and visual communication of a two stage alarm condition.

Downloads

Datasheet Datasheet.pdf
Installation Manual D118-01-001-IS_Issue_2__AB105STR_.pdf
Russian EAC Declaration of Conformity D-GB.GA05.B.12595-20-24.03.2025.pdf
Russian Maritime register 19.00193.278.pdf
Declaration of Conformity DC-027_Issue_F_Spectralarm.pdf
2D drawing (PDF) D118-05-001_Issue_1.pdf
2D drawing (DWG) D118-05-001_Issue_1.DWG
3D drawing (STEP) D118-05-001-3D_Issue_A.STEP
Wiring Schematic DC voltage D118-06-001_Issue_2_AB105_DC.pdf
Wiring Schematic AC voltage D118-06-005_Issue_1_AB105_AC.pdf

Features

  • Automatic synchronisation on multi-sounder system
  • Synchronised flash rates
  • Continuously rated
  • Stainless steel fixings
  • Unit can be mounted using external lugs or internal fixing positions
  • Dual M20x1.5mm threaded cable entries – adaptors available
  • Duplicate pluggable cable terminations – Class A
  • Diode polarized for use in supervised circuits
  • 64 alarm tone frequencies and 4 remotely activated alarm stages
  • Available with custom tone configurations and frequencies
  • Can be mounted in any orientation

Specification

Alarm Horn:
Maximum output: 113dB(A) @ 1 m ±3dB [104dB(A) @ 10ft/3m ±3dB]
Nominal output: 106dB(A) @ 1m ±3dB [97dB(A) @ 10ft/3m ±3dB]
No. of tones: 64 (UKOOA / PFEER compliant)
No. of stages: 4
Volume control: -12dB(A) tone dependent
Effective range: 58m/190ft @ 1KHz
In rush: 636mA within 4.0ms @ 24Vdc
Stage switching: Negative (common positive)
Xenon Beacon:
Energy: 5 Joules (5Ws)
Flash rate: 1Hz (60 fpm)
DC units: Optionally 1.5Hz & double strike
Synchronisation: 1Hz flash rate automatically synchronised
Peak Candela: 500,000 cd – calculated from energy (J)
Eff. Intensity cd: 250 cd – calculated from energy (J)
Peak Candela: 49,788 cd* – measured ref. to I.E.S.
Eff. Intensity cd: 125 cd* – measured ref. to I.E.S.
Tube life: 70% emissions after 8 million flashes
General:
Ingress protection: IP65
Enclosure: High impact UL94 V0 & 5VA FR ABS/PC
Lens colour filter: Field replaceable UV stable PC
Terminals: 0.5 – 2.5mm² (20-14 AWG)
Line monitoring: Diode polarized for use in supervised circuits
Operating: -40 to +66°C [-40° to +151°F]
Storage: -40 to +70°C [-40° to +158°F]
Relative humidity: 95% at 20°C [68°F]
Weight DC: 1.00kg / 2.20Ibs
Weight AC: 1.25kg / 2.75Ibs

Current Consumption

Product Version: Nominal Voltage: Voltage Range: Beacon Current: Horn Current:
DC012 12Vdc 10-15Vdc 600mA 17mA
DC024 24Vdc 20-28Vdc 300mA 33.5mA
DC048 48Vdc 42-54Vdc 250mA 113mA
AC024 24Vac 22-26Vac 50/60Hz 300mA 42.5mA
AC115 115Vac ±10% 50/60Hz 70mA 25mA
AC230 230Vac ±10% 50/60Hz 35mA 17mA

Part Codes

Variable: Identifier: Description:
Product type: AB105STR Combined alarm horn sounder & Xenon strobe
Voltage: DC012
DC024
DC048
AC024
AC115
AC230
12Vdc (10-15Vdc)
24Vdc (20-28Vdc)
48Vdc (42-54Vdc)
24Vac 50/60Hz
115Vac 50/60Hz
230Vac 50/60Hz
Back box/cable entries: [e] A
B
Back box with mounting lugs – 2 x M20x1.5mm entries
Back box with mounting lugs – 2 × 1/2"NPT (adaptors)
Stopping plug material: [m] A ABS
Equip. tag/Duty label: [s] 0
1
2
No equip. tag or Duty label
316 (A4) St/St Equip. tag/Duty label
Metalised Polyester Equip. tag/Duty label
Product version:
[v]
A RMRS, EAC, CE, UKCA
Product option:
[o]
1
X
Z
Standard product
Custom configuration – contact E2S
Custom alarm tone software – contact E2S
Enclosure: [x] R
G
Red (RAL 3000)
Grey (RAL7038)
Lens colour: [y] A
B
C
G
M
R
Y
Amber
Blue
Clear
Green
Magenta
Red
Yellow

Approvals

  • UKCA
  • CE
  • EAC: CU TR 04/2011 CU TR 20/2011
  • Russian Marine Register of Shipping

Tone Table

Stage 1 WAV file Frequency Description. Stage 2 Stage 3 Stage 4
T 1 1000 Continuous – PFEER Toxic Gas Any T 2 T 44
T 2 1200/500 @ 1Hz Sweeping – DIN / PFEER P.T.A.P. Any T 3 T 44
T 3 1000 @ 0.5Hz (1s on, 1s off) Intermittent – PFEER Gen. Alarm Any T 2 T 44
T 4 1.4KH-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s – NF C 48-265 Any T 24 T 1
T 5 544(100mS)/440 (400mS) – NF S 32-001 Any T 19 T 1
T 6 1500/500 – (0.5s on , 0.5s off) x3 + 1s gap – AS4428 Any T 44 T 1
T 7 500-1500Hz Sweeping 2 sec on 1 sec off – AS4428 Any T 44 T 1
T 8 500/1200Hz @ 0.26Hz(3.3s on, 0.5s off) – NEN 2575 Any T 24 T 35
T 9 1000 (1s on, 1s off)x7 + (7s on, 1s off) – IMO Code 1a Any T 34 T 1
T 10 1000 (1s on, 1s off)x7 + (7s on, 1s off) – IMO Code 1a Any T 34 T 1
T 11 420(0.5s on, 0.5s off)x3 + 1s gap – ISO 8201 Temporal Any T 1 T 8
T 12 1000(0.5s on, 0.5s off)x3 + 1s gap – ISO 8201 Temporal Any T 1 T 8
T 13 422/775 – (0.85 on, 0.5 off) x3 + 1s gap – NFPA Temporal Any T 1 T 8
T 14 1000/2000 @ 1Hz – Singapore Any T 3 T 35
T 15 300 Continuous Any T 24 T 35
T 16 440 Continuous Any T 24 T 35
T 17 470 Continuous Any T 24 T 35
T 18 500 Continuous – IMO code 2 (Low) Any T 24 T 35
T 19 554 Continuous Any T 24 T 35
T 20 660 Continuous Any T 24 T 35
T 21 800 Continuous – IMO code 2 (High) Any T 24 T 35
T 22 1200 Continuous Any T 24 T 35
T 23 2000 Continuous Any T 3 T 35
T 24 2400 Continuous Any T 20 T 35
T 25 440 @ 0.83Hz (0.60s on, 0.60s off) Intermittent Any T 44 T 8
T 26 470 @ 0.9Hz (0.55s on, 0.55s off) Intermittent Any T 44 T 8
T 27 470 @ 5Hz (0.10s on, 0.10s off) Intermittent Any T 44 T 8
T 28 544 @ 1.14Hz (0.43s on, 0.44s off) Intermittent Any T 24 T 8
T 29 655 @ 0.875Hz (0.57s on, 0.57s off) Intermittent Any T 44 T 8
T 30 660 @ 0.28Hz (1.80s on, 1.80s off) Intermittent Any T 24 T 8
T 31 660 @ 3.3Hz (0.15s on, 0.15s off) Intermittent Any T 24 T 8
T 32 745 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T 24 T 8
T 33 800 (0.25s on, 1.00s off) Intermittent Any T 24 T 8
T 34 800 @ 2Hz (0.25s on, 0.25s off) – IMO code 3.a (High) Any T 24 T 8
T 35 1000 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T 24 T 8
T 36 2400 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T 24 T 8
T 37 2900 @ 5Hz (0.10s on, 0.10s off) Intermittent Any T 24 T 8
T 38 363/518 @ 1Hz (0.50s / 0.50s) Alternating Any T 8 T 19
T 39 450/500 @ 2Hz (0.25s / 0.25s) Alternating Any T 8 T 19
T 40 554/440 @ 1Hz (0.50s / 0.50s) Alternating Any T 24 T 19
T 41 554/440 @ 0.65Hz (0.76s / 0.76s) Alternating Any T 8 T 19
T 42 561/760 @ 0.83Hz (0.60s / 0.60s) Alternating Any T 8 T 19
T 43 780/600 @ 0.96Hz (0.52s / 0.52s) Alternating Any T 8 T 19
T 44 800/1000 @ 2Hz (0.25s / 0.25s) Alternating Any T 24 T 19
T 45 970/800 @ 2Hz (0.25s / 0.25s) Alternating Any T 8 T 19
T 46 800/1000 @ 0.875Hz (0.57s / 0.57s) Alternating Any T 24 T 19
T 47 2400/2900 @ 2Hz (0.25s / 0.25s) Alternating Any T 24 T 19
T 48 500/1200 @ 0.3Hz (1.67s / 1.67s) Sweeping Any T 24 T 12
T 49 560/1055 @ 0.18Hz (2.73s / 2.73s) Sweeping Any T 24 T 12
T 50 560/1055 @ 3.3Hz (0.15s / 0.15s) Sweeping Any T 24 T 12
T 51 600/1250 @ 0.125Hz (4s / 4s) Sweeping Any T 24 T 12
T 52 660/1200 @ 1Hz (0.50s / 0.50s) Sweeping Any T 24 T 12
T 53 800/1000 @ 1Hz (0.50s / 0.50s) Sweeping Any T 24 T 12
T 54 800/1000 @ 7Hz (0.07s / 0.07s) Sweeping Any T 24 T 12
T 55 800/1000 @ 50Hz (0.01s / 0.01s) Sweeping Any T 24 T 12
T 56 2400/2900 @ 7Hz (0.07s / 0.07s) Sweeping Any T 24 T 12
T 57 2400/2900 @ 1Hz (0.50s / 0.50s) Sweeping Any T 24 T 12
T 58 2400/2900 @ 50Hz (0.01s / 0.01s) Sweeping Any T 24 T 12
T 59 2500/3000 @ 2Hz (0.25s / 0.25s) Sweeping Any T 24 T 12
T 60 2500/3000 @ 7.7Hz (0.65s / 0.65s) Sweeping Any T 24 T 12
T 61 800Hz Motor Siren Any T 24 T 12
T 62 1200Hz Motor Siren Any T 24 T 12
T 63 2400Hz Motor Siren Any T 24 T 12
T 64 Simulated Bell Any T 21 T 12
For Stage 2 any Stage 1 alarm tone sound can be selected.
Country specific or custom tone configurations and alarm frequencies are available upon request.