Datasheet | Datasheet.pdf |
Installation Manual | D207-01-501-IS_Issue_5__MC1X05_.pdf |
-Install manual Telephone-Relay version [T] | D207-01-581-IS_Issue_3__MC1X05-T_.pdf |
Russian EAC Declaration of Conformity | D-GB.GA05.B.12595-20-24.03.2025.pdf |
Russian Fire certificate | GOST-R_POCC_GB.05.H00144_Industrial.PDF |
Russian Maritime register | 19.00193.278.pdf |
Declaration of Conformity | DC-028_Issue_J_Marine.pdf |
2D drawing (PDF) | D207-05-501_Issue_A.pdf |
2D drawing (DWG) | D207-05-501_Issue_A.dwg |
3D drawing (STEP) | D207-05-501-3D_Issue_A.STEP |
Wiring Schematic DC voltage | D207-06-501_Issue_C.pdf |
Wiring Schematic AC voltage | D207-06-505_Issue_A__MC1X05-AC_.pdf |
Pole Mount & Sun Shade Drawing | D217-05-671_Issue_2__MC1_F_.pdf |
Alarm Horn Sounder: | |
---|---|
Maximum output: | 117dB(A) @ 1 m +/- 3dB [108dB(A) @ 10ft/3m +/- 3dB] |
Nominal output: | 114dB(A) @ 1m +/- 3dB [103dB(A) @ 10ft/3m] +/- 3dB |
No. of tones: | 64 (UKOOA / PFEER compliant) |
No. of stages: | 4 |
Volume control: | Full range control |
Effective range: | 108m/355ft @ 1KHz |
Stage switching: | Negative, positive, voltage free |
Xenon Strobe Beacon: | |
Energy: | 5 Joules(5Ws) |
Flash rate: | 1Hz (60 fpm) |
Peak Candela: | 500,000 cd – calculated from energy (J) |
Eff. Intensity cd: | 250 cd – calculated from energy (J) |
Peak Candela: | 39,463 cd* – measured ref. to I.E.S. |
Eff. Intensity cd: | 120 cd* – measured ref. to I.E.S. |
Lens colours: | Amber, Blue, Clear, Green, Magenta, Red & Yellow |
General: | |
Ingress protection: | IP66 & IP67 Type 4/4X/13 |
Enclosure material: | High impact UL94 V0 & 5VA FR ABS |
Enclosure colour: | Grey (RAL7038) or Red (RAL3000 |
Dome material: | Borosilicate glass |
Lens colour filter: | Field replaceable UV stable PC |
Lens guard: | 316 (A4) Stainless steel |
Cable entries: | 2 x M20; 1 x M20 & 1 × 1/2"NPT; 2 × 1/2"NPT supplied with blanking plug |
Terminals: | 0.5 – 2.5mm² (20-14 AWG) |
Line monitoring: | Diode polarized for use in supervised circuits |
Operating temp: | -40 to +66°C [-40° to +151°F] |
Storage temp: | -40 to +70°C [-40° to +158°F] |
Relative humidity: | 95% at 20°C [68°F] |
Weight : | DC: 3.00kg/6.6Ibs AC:3.50kg/7.7Ibs |
*Candela measurements representative of performance with clear lens at optimum voltage |
Product Version: | Nominal Voltage: | Voltage Range: | Beacon Current: | Horn Current: |
---|---|---|---|---|
DC012 | 12V dc | 10-14V dc | 550mA | 280mA |
DC024 | 24V dc | 20-28V dc | 300mA | 224mA |
DC048 | 48Vdc | 42-54V dc | 180mA | 122mA |
AC115 | 115Vac | ±10% 50/60Hz | 140mA | 100mA |
AC230 | 230V ac | ±10% 50/60Hz | 55mA | 64mA |
Variable: | Identifier: | Description: |
---|---|---|
Product type: | MC1X05 | Combined alarm horn sounder & Xenon strobe |
Type: | F | Flare re-entrant horn |
Voltage: | AC115 AC230 DC012 DC024 DC048 |
115V ac 50/60Hz 230V ac 50/60Hz 12V dc (10-14Vdc) 24V dc (20-28Vdc) 48V dc (42-54Vdc) |
Cable entries: [e] | A B C |
M20x1.5 & ½” NPT M20x1.5 & M20x1.5 (Default) ½” NPT & ½” NPT |
Stopping plug material: [m] | N | Nylon |
Bracket & Guard: [s] | 1 3 |
316 (A4) Stainless Steel 316 (A4) Stainless Steel with Equipment tag |
Product version: [v] |
A T |
CE, EAC, RMRS Telephone/Relay Initiate – CE, EAC, RMRS |
Product option: [o] |
1 Z X Y |
Standard product Custom alarm tone software – contact E2S Custom configuration – contact E2S Stage control Config. 4 or 8 |
Enclosure colour: [x] | G R S |
Grey Red Special colour – contact E2S |
Lens colour: [y] | A B C G M R Y |
Amber Blue Clear Green Magenta Red Yellow |
Accessories: | ||
SP65-0001-A4 SP65-0003-A4 |
Pole Mount Bracket Kit St/St A4 (316) Sunshade – St/St A4 (316) |
|
Alarm stage control: | ||
Please review the installation manual and wiring schematics for remote stage control and EOL resistor monitoring configuration options: | ||
Config. 1 or 5 [DC]: | Factory default. Common negative, positive switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only | |
Config. 2 or 6 [DC]: | User setting. Common positive, negative switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only | |
Config. 3 or 7 [DC]: | User setting. Common negative, positive switching activation of Alarm Stages 1 & 2 with EOL on both stages. Reverse polarity monitoring | |
Config. 4 or 8 [DC]: | Product option ‘Y’. Independent activation of Alarm Stages 1 & 2 with EOL on both stages. Forward polarity monitoring | |
Config. 1 or 2 [AC]: | Factory default. Up to 4 Alarm Stages. Stage 1 activated at power on. Stages 2, 3 and 4 via volt free contacts |