Product finder
Product code
Application
Environment
Device
Category
Product
Type
Product finder

Find the right E2S product

Application Environment
  • Application Environment
  • Hazardous Location
  • Safe Area
Device Category
  • Device Category
Product Type
  • Product Type
Search

MC1X05F Alarm Horn & Xenon Strobe 2-31-400

Product image
Product Image
Product Image
The MC1X05F combines a high output, 117dB(A) alarm sounder with a 5 Joule Xenon strobe beacon. Featuring a robust, fire retardant, IP66 & IP67 housing, the MC1X05F is particularly suitable for harsh environments with high ambient noise levels.
Request a quote for this product
Horn Type
Voltage
Cable Entry Type
Stopping plug/adaptor material
Bracket & Guard
Product version
Product option
Enclosure Color
Lens Color
Part Number:
MC1X05
Request Price or enquire about this product
Enquire about
Alarm Horn & Xenon Strobe

Upgraded Product:

  • 64 alarm tones
  • 4 remotely activated alarm stages
  • Low in-rush
  • Auto-synchronised output
  • 316 (A4) mounting bracket
  • Pluggable, duplicated cable terminals

Description

The flare horn on the MC1X05F produces sound level outputs up to 117dB(A) at 1 metre with a choice of 64 alarm tones and 4 remotely selectable stages. The Xenon strobe beacon automatically synchronises with other MC1X05F devices on the same power supply. The sounder & beacon can be operated individually or simultaneously.

Downloads

Datasheet Datasheet.pdf
Installation Manual D207-01-501-IS_Issue_5__MC1X05_.pdf
-Install manual Telephone-Relay version [T] D207-01-581-IS_Issue_3__MC1X05-T_.pdf
Russian EAC Declaration of Conformity D-GB.GA05.B.12595-20-24.03.2025.pdf
Russian Fire certificate GOST-R_POCC_GB.05.H00144_Industrial.PDF
Russian Maritime register 19.00193.278.pdf
Declaration of Conformity DC-028_Issue_J_Marine.pdf
2D drawing (PDF) D207-05-501_Issue_A.pdf
2D drawing (DWG) D207-05-501_Issue_A.dwg
3D drawing (STEP) D207-05-501-3D_Issue_A.STEP
Wiring Schematic DC voltage D207-06-501_Issue_C.pdf
Wiring Schematic AC voltage D207-06-505_Issue_A__MC1X05-AC_.pdf
Pole Mount & Sun Shade Drawing D217-05-671_Issue_2__MC1_F_.pdf

Features

  • Ingress protection IP66/67 Type 4/4X/13
  • Glass lenses & 316 (A4) Stainless steel guard
  • UV stable PC, field replaceable, colour lens filter
  • Large termination area
  • Dual M20 or 1/2"NPT cable entries – adaptors available
  • Stopping plug included
  • 316 (A4) Stainless steel mounting bracket
  • Ratchet adjustable ‘U’ bracket for 360° positioning
  • Duplicate cable terminations
  • Reverse polarity diode fitted
  • Continuously rated
  • Automatic synchronisation
  • 64 alarm tone frequencies and 4 remotely activated alarm stages
  • Positive or negative stage activation switching
  • Alternative activation configurations available
  • Available with custom tone configurations and frequencies
  • Alarm horn/sounder & beacon can be operated individually or simultaneously

Specification

Alarm Horn Sounder:
Maximum output: 117dB(A) @ 1 m +/- 3dB
[108dB(A) @ 10ft/3m +/- 3dB]
Nominal output: 114dB(A) @ 1m +/- 3dB
[103dB(A) @ 10ft/3m] +/- 3dB
No. of tones: 64 (UKOOA / PFEER compliant)
No. of stages: 4
Volume control: Full range control
Effective range: 108m/355ft @ 1KHz
Stage switching: Negative, positive, voltage free
Xenon Strobe Beacon:
Energy: 5 Joules(5Ws)
Flash rate: 1Hz (60 fpm)
Peak Candela: 500,000 cd – calculated from energy (J)
Eff. Intensity cd: 250 cd – calculated from energy (J)
Peak Candela: 39,463 cd* – measured ref. to I.E.S.
Eff. Intensity cd: 120 cd* – measured ref. to I.E.S.
Lens colours: Amber, Blue, Clear, Green, Magenta, Red & Yellow
General:
Ingress protection: IP66 & IP67 Type 4/4X/13
Enclosure material: High impact UL94 V0 & 5VA FR ABS
Enclosure colour: Grey (RAL7038) or Red (RAL3000
Dome material: Borosilicate glass
Lens colour filter: Field replaceable UV stable PC
Lens guard: 316 (A4) Stainless steel
Cable entries: 2 x M20; 1 x M20 & 1 × 1/2"NPT; 2 × 1/2"NPT
supplied with blanking plug
Terminals: 0.5 – 2.5mm² (20-14 AWG)
Line monitoring: Diode polarized for use in supervised circuits
Operating temp: -40 to +66°C [-40° to +151°F]
Storage temp: -40 to +70°C [-40° to +158°F]
Relative humidity: 95% at 20°C [68°F]
Weight : DC: 3.00kg/6.6Ibs AC:3.50kg/7.7Ibs
*Candela measurements representative of performance with clear lens at optimum voltage

Current Consumption

Product Version: Nominal Voltage: Voltage Range: Beacon Current: Horn Current:
DC012 12V dc 10-14V dc 550mA 280mA
DC024 24V dc 20-28V dc 300mA 224mA
DC048 48Vdc 42-54V dc 180mA 122mA
AC115 115Vac ±10% 50/60Hz 140mA 100mA
AC230 230V ac ±10% 50/60Hz 55mA 64mA

Part Codes

Variable: Identifier: Description:
Product type: MC1X05 Combined alarm horn sounder & Xenon strobe
Type: F Flare re-entrant horn
Voltage: AC115
AC230
DC012
DC024
DC048
115V ac 50/60Hz
230V ac 50/60Hz
12V dc (10-14Vdc)
24V dc (20-28Vdc)
48V dc (42-54Vdc)
Cable entries: [e] A
B
C
M20x1.5 & ½” NPT
M20x1.5 & M20x1.5 (Default)
½” NPT & ½” NPT
Stopping plug material: [m] N Nylon
Bracket & Guard: [s] 1
3
316 (A4) Stainless Steel
316 (A4) Stainless Steel with Equipment tag
Product version:
[v]
A
T
CE, EAC, RMRS
Telephone/Relay Initiate – CE, EAC, RMRS
Product option:
[o]
1
Z
X
Y
Standard product
Custom alarm tone software – contact E2S
Custom configuration – contact E2S
Stage control Config. 4 or 8
Enclosure colour: [x] G
R
S
Grey
Red
Special colour – contact E2S
Lens colour: [y] A
B
C
G
M
R
Y
Amber
Blue
Clear
Green
Magenta
Red
Yellow
Accessories:
SP65-0001-A4
SP65-0003-A4
Pole Mount Bracket Kit St/St A4 (316)
Sunshade – St/St A4 (316)
Alarm stage control:
Please review the installation manual and wiring schematics for remote stage control and EOL resistor monitoring configuration options:
Config. 1 or 5 [DC]: Factory default. Common negative, positive switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only
Config. 2 or 6 [DC]: User setting. Common positive, negative switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only
Config. 3 or 7 [DC]: User setting. Common negative, positive switching activation of Alarm Stages 1 & 2 with EOL on both stages. Reverse polarity monitoring
Config. 4 or 8 [DC]: Product option ‘Y’. Independent activation of Alarm Stages 1 & 2 with EOL on both stages. Forward polarity monitoring
Config. 1 or 2 [AC]: Factory default. Up to 4 Alarm Stages. Stage 1 activated at power on. Stages 2, 3 and 4 via volt free contacts

Approvals

  • EAC compliant: RU D-GB.GA05.B.12595-20
  • Russian Maritime Register of Shipping
    Cert: No. 19.00193.278

Tone Table

Stage 1 WAV file Frequency Description. Stage 2 Stage 3 Stage 4
T 1 1000 Continuous – PFEER Toxic Gas T 3 T 2 T 44
T 2 1200/500 @ 1Hz Sweeping – DIN / PFEER P.T.A.P. T 1 T 3 T 44
T 3 1000 @ 0.5Hz (1s on, 1s off) Intermittent – PFEER Gen. Alarm T 1 T 2 T 44
T 4 1.4KH-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s – NF C 48-265 T 44 T 24 T 1
T 5 544(100mS)/440 (400mS) – NF S 32-001 T 52 T 19 T 1
T 6 1500/500 – (0.5s on , 0.5s off) x3 + 1s gap – AS4428 T 7 T 44 T 1
T 7 500-1500Hz Sweeping 2 sec on 1 sec off – AS4428 T 6 T 44 T 1
T 8 500/1200Hz @ 0.26Hz(3.3s on, 0.5s off) – NEN 2575 T 44 T 24 T 35
T 9 1000 (1s on, 1s off)x7 + (7s on, 1s off) – IMO Code 1a T 18 T 34 T 1
T 10 1000 (1s on, 1s off)x7 + (7s on, 1s off) – IMO Code 1a T 21 T 34 T 1
T 11 420(0.5s on, 0.5s off)x3 + 1s gap – ISO 8201 Temporal T 44 T 1 T 8
T 12 1000(0.5s on, 0.5s off)x3 + 1s gap – ISO 8201 Temporal T 44 T 1 T 8
T 13 422/775 – (0.85 on, 0.5 off) x3 + 1s gap – NFPA Temporal T 44 T 1 T 8
T 14 1000/2000 @ 1Hz – Singapore T 23 T 3 T 35
T 15 300 Continuous T 44 T 24 T 35
T 16 440 Continuous T 44 T 24 T 35
T 17 470 Continuous T 44 T 24 T 35
T 18 500 Continuous – IMO code 2 (Low) T 44 T 24 T 35
T 19 554 Continuous T 64 T 24 T 35
T 20 660 Continuous T 44 T 24 T 35
T 21 800 Continuous – IMO code 2 (High) T 44 T 24 T 35
T 22 1200 Continuous T 44 T 24 T 35
T 23 2000 Continuous T 15 T 3 T 35
T 24 2400 Continuous T 48 T 20 T 35
T 25 440 @ 0.83Hz (0.60s on, 0.60s off) Intermittent T 1 T 44 T 8
T 26 470 @ 0.9Hz (0.55s on, 0.55s off) Intermittent T 1 T 44 T 8
T 27 470 @ 5Hz (0.10s on, 0.10s off) Intermittent T 1 T 44 T 8
T 28 544 @ 1.14Hz (0.43s on, 0.44s off) Intermittent T 44 T 24 T 8
T 29 655 @ 0.875Hz (0.57s on, 0.57s off) Intermittent T 1 T 44 T 8
T 30 660 @ 0.28Hz (1.80s on, 1.80s off) Intermittent T 44 T 24 T 8
T 31 660 @ 3.3Hz (0.15s on, 0.15s off) Intermittent T 30 T 24 T 8
T 32 745 @ 1Hz (0.50s on, 0.50s off) Intermittent T 44 T 24 T 8
T 33 800 (0.25s on, 1.00s off) Intermittent T 53 T 24 T 8
T 34 800 @ 2Hz (0.25s on, 0.25s off) – IMO code 3.a (High) T 56 T 24 T 8
T 35 1000 @ 1Hz (0.50s on, 0.50s off) Intermittent T 44 T 24 T 8
T 36 2400 @ 1Hz (0.50s on, 0.50s off) Intermittent T 21 T 24 T 8
T 37 2900 @ 5Hz (0.10s on, 0.10s off) Intermittent T 53 T 24 T 8
T 38 363/518 @ 1Hz (0.50s / 0.50s) Alternating T 1 T 8 T 19
T 39 450/500 @ 2Hz (0.25s / 0.25s) Alternating T 1 T 8 T 19
T 40 554/440 @ 1Hz (0.50s / 0.50s) Alternating T 44 T 24 T 19
T 41 554/440 @ 0.65Hz (0.76s / 0.76s) Alternating T 1 T 8 T 19
T 42 561/760 @ 0.83Hz (0.60s / 0.60s) Alternating T 1 T 8 T 19
T 43 780/600 @ 0.96Hz (0.52s / 0.52s) Alternating T 1 T 8 T 19
T 44 800/1000 @ 2Hz (0.25s / 0.25s) Alternating T 5 T 24 T 19
T 45 970/800 @ 2Hz (0.25s / 0.25s) Alternating T 1 T 8 T 19
T 46 800/1000 @ 0.875Hz (0.57s / 0.57s) Alternating T 53 T 24 T 19
T 47 2400/2900 @ 2Hz (0.25s / 0.25s) Alternating T 57 T 24 T 19
T 48 500/1200 @ 0.3Hz (1.67s / 1.67s) Sweeping T 44 T 24 T 12
T 49 560/1055 @ 0.18Hz (2.73s / 2.73s) Sweeping T 44 T 24 T 12
T 50 560/1055 @ 3.3Hz (0.15s / 0.15s) Sweeping T 44 T 24 T 12
T 51 600/1250 @ 0.125Hz (4s / 4s) Sweeping T 44 T 24 T 12
T 52 660/1200 @ 1Hz (0.50s / 0.50s) Sweeping T 64 T 24 T 12
T 53 800/1000 @ 1Hz (0.50s / 0.50s) Sweeping T 56 T 24 T 12
T 54 800/1000 @ 7Hz (0.07s / 0.07s) Sweeping T 57 T 24 T 12
T 55 800/1000 @ 50Hz (0.01s / 0.01s) Sweeping T 54 T 24 T 12
T 56 2400/2900 @ 7Hz (0.07s / 0.07s) Sweeping T 57 T 24 T 12
T 57 2400/2900 @ 1Hz (0.50s / 0.50s) Sweeping T 47 T 24 T 12
T 58 2400/2900 @ 50Hz (0.01s / 0.01s) Sweeping T 54 T 24 T 12
T 59 2500/3000 @ 2Hz (0.25s / 0.25s) Sweeping T 44 T 24 T 12
T 60 2500/3000 @ 7.7Hz (0.65s / 0.65s) Sweeping T 44 T 24 T 12
T 61 800Hz Motor Siren T 44 T 24 T 12
T 62 1200Hz Motor Siren T 44 T 24 T 12
T 63 2400Hz Motor Siren T 44 T 24 T 12
T 64 Simulated Bell T 44 T 21 T 12
Country specific or custom tone configurations and alarm frequencies are available upon request.