D1xB2X15 Explosion Proof Xenon Strobe Beacon 15J 1-21-204

Product Image
Product Image
Product Image
The D1xB2X15 is a globally approved explosion proof 15 Joule Xenon beacon. The robust Type 4/4X corrosion proof LM6 marine grade aluminium alloy enclosure ensures suitability for all Class I/II Div 1, Zone 1, 2, 21 & 22 applications.
Request a quote for this product
Type
Voltage
Cable entries
Stopping plug/adaptor material
Guard material
Product version
Product option
Enclosure colour
Lens colour
Part Number:
D1xB2
Request Price or enquire about this product
Enquire about
Explosion Proof Xenon Strobe Beacon 15J

Description

Approved to UL1638 and CAN/ULC S526 for fire alarm use the D1xB2X15 beacons produce a high output Xenon flash required for effective signalling in environments with elevated levels of ambient light. The field replaceable colour filter enhances the strobe and is constructed from UV stable PC. The robust enclosure features a threaded flame path, four cable entries. Mounting options include surface via integrated lugs, pendant or by addition of optional multi direction stainless steel bracket. SIL1 & SIL2 Route 2H compliant to IEC61508 (2010) as standard, with optional diagnostic module for Route 1H SIL2 compliance.

Downloads

Datasheet Datasheet.pdf
Install manual: Product version [A] D191-01-201-IS_Issue_3__D1xB2X_.pdf
Install manual: Product version [S] D191-01-621-IS_Issue_1__D1xB2-S_.pdf
-Install manual Telephone-Relay version [T] D191-01-581-IS_Issue_1__D1xB2-T_.pdf
Installation Manual - Russia D191-00-201-IS-RUS_Issue_2_D1xB2X.pdf
Manual de Instrucciones - Espanola D191-00-201-IS-ESP_Issue_2D1xB2X05-10-15-21.pdf
Mode d'emploi - Francais D191-00-201-IS-FRE_Issue_2_D1XB2X05-10-15-21.pdf
Installation manual - Chinese D191-00-201-IS-CHN_Issue_2__D1xB2X05-10-15-21_.pdf
IECEx certificate IECEx_ULD_19.0006X_Issue_3_D1xB_J_H__D2xH.pdf
ATEX certificate DEMKO_19_ATEX_2009X_Issue_3_D1xB_J_H__D2xH.pdf
UL certificate of compliance UL_CoC_-_20190517-E245313_Vol.1_Sec.3_D1xB2-J2.pdf
CSFM Listing CSFM_Listing_2279-0508_D1xB2_2025.pdf
UKCA Certificate UL21UKEX2130X_Rev._3_D1xB_J_H__D2xH.pdf
CCCEx Certificate EN CCCEx_Certificate_EN_Iss001_D1xB2_2027.01.26.pdf
CCCEx Certificate CN CCCEx_Certificate_CN_Iss001_D1xB2_2027.01.26.pdf
Russian Ex certificate C_RU_C-GB.71..00273_20.pdf
Russian Fire certificate EAC043-RU_C-GB.68.B.00879-22__D1xB2_.pdf
CCOE PESO CCOE_P493433-1_D1xB2.pdf
ECAS Ex Approval 24-08-120918_E24-08-125041_NB0007_D1xB__D1xH.pdf
Ingress Protection certificate TL23065A_E2S_IP66_and_IPX7.pdf
Declaration of Conformity DC-077_Issue_G_D1xB2.pdf
Declaration of Conformity UKCA DC-096_Issue_A_D1xB2_UKCA.pdf
SIL Certificate: Product version [A] T900-123_4_SIL2_SIL1_2H__D1xB2_STExB2_GNExB_BExBG_.pdf
SIL Certificate: Product version [S] T727-041-3_SIL2_1H__BExBG_D1xB2_GNExB2_STExB2_.pdf
2D drawing (PDF) D191-05-201_Issue_4.pdf
2D drawing (DWG) D191-05-201_Issue_4.dwg
Bracket Accessory D191-05-211_Issue_2.pdf
3D drawing (STEP) D191-05-201-3D_Issue_1.STEP
3D drawing (STEP) D191-05-211-3D_Issue_1.STEP
Wiring Schematic D191-06-201_Issue_D.pdf
Wiring schematic: Product version [S] D191-06-621_Issue_1.pdf
Nameplate Drawing D191-09-215_Issue_1_D1xB2X15.pdf
Equipment Tag Drawing D254-00-101_Issue_1.pdf
Duty Label Drawing D254-00-001_Issue_1.pdf
Pole Mount & Sun Shade Drawing D217-05-265_Issue_1__D1xB2_.pdf

Features

  • Four flash rates: 1Hz, 1.3Hz, 1.5Hz & double flash
  • Automatic synchronisation on multi-beacon system
  • A4 316 Stainless Steel guard included as standard
  • UV stable polycarbonate lens colour filter – field replaceable
  • 4 x side, 1 x pendant cable entries – stopping plugs included
  • Corrosion proof marine grade aluminium enclosure
  • UL 1638 & CAN/ULC S526 signaling device for Fire Alarm

Specification

Source: Xenon Strobe – Single or Dual
Energy: 15 Joules (15Ws)
Flash rates: 1Hz flash (60 fpm)
1.3Hz flash (80 fpm)
1.5Hz flash (90 fpm)
Double flash (120 fpm)
Eff. Intensity cd: 98.61cd UL1638 Private mode fire
Eff. Intensity cd: 731.71cd measured ref to I.E.S
Eff. Intensity cd: 750 cd – calculated from energy (J)
Peak Candela: 1,500,000 cd – calculated from energy (J)
Lens colours: Amber, Blue, Clear, Green, Magenta, Red & Yellow
Voltage DC: 24V dc (20-28Vdc), 48Vdc (42-54Vdc)
Voltage AC: 115Vac (110-120Vac), 230Vac (220-240Vac)
In-rush: 753mA within 6ms @ 24Vdc, 1958mA within 4.3ms @ 48Vdc
Safety Integrity Level: Product version A: SIL1 and SIL2 Route 2H
Product version S: SIL2 Route 1H with diagnostics SFF: >99%
See install manual for reliability & functional safety data
Ingress protection: IP rating per EN60529:IP66/67
Type rating per UL50E/NEMA250:4/4X/3R/13
Lens material: High impact Borosilicate glass
Enclosure material: Marine grade LM6 aluminium alloy
Enclosure colour: Red or Grey, custom colours available on request
Enclosure finish: Chromate & powder coated finish
Cable entries: Side: 2 × 3/4"NPT & 2 x M20x1.5mm
Pendant: 1 × 3/4"NPT
Stopping plugs included
Stopping plugs: Brass, Nickel Plated or Stainless Steel
Terminals: 0.5 – 2.5mm² (20-14AWG) – 12AWG solid core conductor
Duplicated terminals
Line monitoring: Blocking diode included
EOL Min. 500 Ohm 2W, or 3k3 Ohm 0.5W resistor
or diode (DC versions) can be fitted
Ground/Earth stud: M5
Enclosure volume: <2 litres
Installation temp: -55 to +80°C [-67° to +176°F]
Storage temp: -55 to +80°C [-67° to +176°F]
Relative humidity: 99% – tropicalised/conformal coated electronics
MTBF DC: 198.88 years / 1,742,161 hours – MIL 217
MTBF AC: 253.68 years / 2,222,223 hours – MIL 217
Weight: 3.2kg/7.1Ibs
*All candela data is representative of performance with clear lens at optimum voltage.

Current Consumption

Nominal
Voltage:
Voltage
range:
Nominal
current:
Max.
current:
In-rush:
24Vdc 20-28Vdc 853mA 920mA 813mA <6ms
48Vdc 42-54Vdc 330mA 360mA 1958mA <4.3ms
115Vac 110-120Vac 50/60Hz 310mA 420mA -
230Vac 220-240Vac 50/60Hz 170mA 230mA -

Part Codes

Part Code: Identifier: Description:
Product type: D1xB2
Type: X15 Xenon Strobe Beacon 15 Joule
Voltage: DC024
DC048
AC115
AC230
24Vdc (20-28Vdc)
48Vdc (42-54Vdc)
115Vac (110-120Vac)
230Vac (220-240Vac)
Cable entries: [e] M
B
E
2 × 3/4"NPT, 2 x M20, 1 × 3/4"NPT
2 × 1/2"NPT – adaptors, 2 × 3/4"NPT, 1 × 3/4"NPT
1 × 1/2"NPT – adaptors, 1 x M20, 2 × 3/4"NPT, 1 × 3/4"NPT
Stopping plug/
adaptor material: [m]
B
N
S
Brass
Nickel plated brass
Stainless steel
Guard material:
[s]
1
3
5
A4 316 Stainless Steel
A4 316 St/St with Equip. Tag
A4 316 St/St with Equip. Tag and Duty Label
Product version:
[v]
A

S


T

U
UL, cUL, ULC, IECEx, ATEX, CCCEx, Ex EAC
PESO, CSFM SIL1 & SIL2 Route 2H
UL, cUL, ULC, IECEx, ATEX, CCCEx, Ex EAC
PESO, CSFM (24Vdc only)
SIL2 Route 1H with diagnostics SFF: >99%
Telephone/Relay Initiate
IECEx, ATEX, Ex EAC, PESO
Dual Xenon Tube IECEx, ATEX, Ex EAC
PESO, SIL1 & SIL2 Route 2H
Product option:
[o]
1
X
Standard product
Custom configuration – contact E2S
Enclosure colour: [x] R
G
S
Red
Grey
Special colour – contact E2S
Lens colour: [y] A
B
C
G
M
R
Y
Amber
Blue
Clear
Green
Magenta
Red
Yellow
Accessories:
SP77-0001-A4-R
SP77-0001-A4-G
SP65-0001-A4
SP65-0003-A4
Multi angle bracket A4 (316) for Red enclosure
Multi angle bracket A4 (316) for Grey enclosure
Pole Mount Bracket Kit St/St A4 (316)
Sunshade – St/St A4 (316)
Spares:
SP77-0002
SP77-0015-R
SP77-0015-G
Xenon flash tube assembly
Pack of 2 x Mounting Lugs – Red enclosure
Pack of 2 x Mounting Lugs – Grey enclosure

Approvals

  • UL/cUL/ULC – File ref: E245313
  • IECEx Certificate: IECEx ULD 19.0006X
  • ATEX Certificate: DEMKO 19 ATEX 2009X
  • UKCA certificate: UL21UKEX2130X
  • CCCEx certificate: 2022122309114969
  • TR CU Ex EAC certificate: EAC RU C-GB.AA.71.B.00273/20
  • PESO CCOE certified: P493433-1
  • CSFM listing: 7300-2279:0508
  • SIL1 & SIL2 compliant to IEC61508 (2010)

Assemblies

The D1xB2X15 is available as a plated assembly configured with a D1x type alarm horn sounder and additional
D1x type Xenon strobe or LED beacons with or without a D1xJ2 Ex d junction box. Contact E2S for further information.

Coding

  • NEC Class / Zone
    Class I Zone 1 AEx db IIC T3 Ta -55°C to +80°C (AC: +65°C)
    Class I Zone 1 AEx db IIC T4 Ta -55°C to +65°C
    Zone 21 AEx tb IIIC T132°C Ta -55°C to +80°C (AC: T153°C +70°C)
  • CEC Class / Zone
    Ex db IIC T3 Ta -55°C to +80°C (AC: +70°C)
    Ex db IIC T4 Ta -55°C to +65°C
    Ex tb IIIC T132°C Ta -55°C to +80°C (AC: T153°C +70°C)
  • NEC / CEC Class / Div
    Class I Div 1 Group ABCD T3C Ta -55°C to +80°C (DC only)
    Class I Div 1 Group ABCD T4 Ta -55°C to +55°C (AC: T4A +55°C)
    Class II Div 1 Group EFG T4 Ta -55°C to +80°C (AC: +40°C)
    Class III Div 1 Ta -55°C to +80°C (AC: +40°C)
  • IECEx / ATEX
    II 2G Ex db IIC T3 Gb Ta -55°C to +80°C (AC: +65°C)
    II 2G Ex db IIC T4 Gb Ta -55°C to +45°C
    II 2D Ex tb IIIC T146°C Db Ta -55°C to +80°C (AC: T139°C +70°C)

Effective Candela lens colour factor

Amber Blue Clear Green Magenta Red Yellow
0.59 0.27 1.00 0.51 0.34 0.15 0.85

Upcoming Events