Datasheet | Datasheet.pdf |
IECEx certificate | IECEx_ULD_14.0004X_007_D2x.pdf |
ATEX certificate | DEMKO_14_ATEX_4786493904X_Rev7_D2x.pdf |
UL certificate of compliance | UL_CoC_-_20140624-E230764_Vol.1_Sec.2_D2xS_C1_L.pdf |
UL certificate of compliance | UL_CoC_-_20171013-E245313_Vol.1_Sec.2_D2xB.pdf |
UKCA Certificate | UL21UKEX2131X_Rev._1_D2x.pdf |
Declaration of Conformity | DC-113_Issue_A_D2xC3_P1.pdf |
Declaration of Conformity UKCA | DC-114_Issue_A_D2xC3_P1_UKCA.pdf |
Install Manual Alarm Horn with 2 beacons and junction box | D215-01-148-IS_Issue_2.pdf |
Install Manual Alarm Horn with 2 beacons no junction box | D215-01-135-IS_Issue_2.pdf |
Install Manual Alarm Horn with 3 beacons and junction box | D215-01-158-IS_Issue_2.pdf |
Install Manual Alarm Horn with 3 beacons no junction box | D215-01-145-IS_Issue_2.pdf |
Install Manual Alarm Horn with 4 beacons no junction box | D215-01-155-IS_Issue_2.pdf |
Outline PDF 2 beacons and junction box | D215-05-148_Issue_2.pdf |
Outline PDF 2 beacons no junction box | D215-05-135_Issue_2.pdf |
Outline PDF 3 beacons and junction box | D215-05-158_Issue_2.pdf |
Outline PDF 3 beacons no junction box | D215-05-145_Issue_2.pdf |
Outline PDF 4 beacons no junction box | D215-05-155_Issue_2.pdf |
Outline DWG 2 beacons and junction box | D215-05-148_Issue_2.DWG |
Outline DWG 2 beacons no junction box | D215-05-135_Issue_2.DWG |
Outline DWG 3 beacons and junction box | D215-05-158_Issue_2.DWG |
Outline DWG 3 beacons no junction box | D215-05-145_Issue_2.DWG |
Outline DWG 4 beacons no junction box | D215-05-155_Issue_2.DWG |
Outline STEP 2 beacons and junction box | D215-05-148_Issue_1.STEP |
Outline STEP 2 beacons no junction box | D215-05-135_Issue_1.STEP |
Outline STEP 3 beacons and junction box | D215-05-158_Issue_1.STEP |
Outline STEP 3 beacons no junction box | D215-05-145_Issue_1.STEP |
Outline STEP 4 beacons no junction box | D215-05-155_Issue_1.STEP |
Wiring PDF 2 beacons and junction box | D215-06-148_Issue_5.pdf |
Wiring PDF 2 beacons no junction box | D215-06-135_Issue_3.pdf |
Wiring PDF 3 beacons and junction box | D215-06-158_Issue_3.pdf |
Wiring PDF 3 beacons no junction box | D215-06-145_Issue_3.pdf |
Wiring PDF 4 beacons no junction box | D215-06-155_Issue_3.pdf |
Equipment Tag Drawing | D254-00-111_Issue_1.pdf |
Duty Label Drawing Option 2 | D254-00-031_Issue_1.pdf |
Duty Label Drawing Option 3 | D254-00-001_Issue_1.pdf |
Product image horn with 2 beacons no junction box Red | D2xC3N1xGxCS1-R.png |
Product image horn with 2 beacons no junction box Grey | D2xC3N1xGxRS1-G.png |
Product image horn with 2 beacons with junction box Red | D2xC3J1xGxCS1-R.png |
Product image horn with 2 beacons with junction box Grey | D2xC3J1xGxRS1-G.png |
Product image horn with 3 beacons no junction box Red | D2xC3N1xGxAxRS1-R.png |
Product image horn with 3 beacons no junction box Grey | D2xC3N1xGxAxRS1-G.png |
Product image horn with 3 beacons with junction box Red | D2xC3J1xGxAxRS1-R.png |
Product image horn with 3 beacons with junction box Grey | D2xC3J1xGxAxRS1-G.png |
Product image horn with 4 beacons no junction box Grey | D2xC3N1xGxBxAxRS1-G.png |
Component: | D2xB1LD2 LED Beacon |
---|---|
Product data: | D2xB1LD2: www.e2s.com/1-31-065 |
Source: | Array of 4 x High Power Cree® LED’s |
Eff. Intensity cd: | 73.4 cd UL1638 Private mode fire |
Eff. Intensity cd: | 180 cd UL1638 General signalling |
Peak Intensity cd: | 300,000 cd |
Eff. Intensity cd: | 87 cd High power steady |
LED life: | >60,000 hours |
Flash rate: | Synchronized 1Hz, 1.3Hz and 2Hz flash rates |
Component: | D2xB1X10 10J Xenon Strobe Beacon |
Product data: | D2xB1X10: www.e2s.com/1-31-050 |
Energy: | 10 Joules (10Ws) |
Flash rate: | 1Hz (60 fpm) |
Peak Candela: | 1,000,000 cd – calculated from energy (J) |
Eff. Intensity cd: | 500 cd – calculated from energy (J) |
Peak Candela: | 101,784 cd* – measured ref. to I.E.S. |
Eff. Intensity cd: | 288.8 cd* – measured ref. to I.E.S. |
Component: | D2xB1X05 5J Xenon Strobe Beacon |
Product data: | D2xB1X05: www.e2s.com/1-31-040 |
Energy: | 5 Joules (5Ws) |
Flash rate: | 1Hz (60 fpm) |
Peak Candela: | 500,000 cd – calculated from energy (J) |
Eff. Intensity cd: | 250 cd – calculated from energy (J) |
Peak Candela: | 33,410 cd* – measured ref. to I.E.S. |
Eff. Intensity cd: | 94.78 cd* – measured ref. to I.E.S. |
Component: | D2xS1 Alarm Horn Sounder |
Product data: | D2xS1: www.e2s.com/1-32-025 |
Maximum output: | 116dB(A) @ 1 metre [107dB(A) @ 10ft/3m] |
Nominal output: | 112dB(A) @ 1m +/- 3dB – Tone 2 [103dB(A) @ 10ft/3m] |
No. of tones: | 64 (UKOOA / PFEER compliant) |
No. of stages: | 4 |
Volume control: | Adjustable -12dB(A) [Tone 2] |
Effective range: | 125m/410ft @ 1KHz |
Stage switching: | DC units: negative or positive. AC units: common supply line |
General: | Common component features: |
Ingress protection: | IP rating per EN60529:IP66 Type rating per UL50E/NEMA250:4/4X/3R/13 |
Enclosure material: | Marine grade aluminium LM6 – copper free Chromated & powder coated – corrosion proof |
Colour: | Red, Grey |
Lens material: | Borosilicate glass dome & PC colour filter |
Guard: | Stainless Steel dome guard as standard |
Stopping plugs: | Brass/Nickel Plated/Stainless Steel plugs included |
Ground/Earth: | M5 |
Terminals: | 0.5 – 2.5mm² (20-14 AWG) |
Line monitoring: | Blocking diode included. EOL can be factory fitted |
Certified temp: | -40 to +50°C [-40° to +122°F] |
Storage temp: | -40 to +70°C [-40° to +158°F] |
Relative humidity: | 95% – Additional tropicalisation is recommended for applications where both high relative humidity and high ambient temperatures exist |
Voltage & Range: | Frequency: | D2xB1LD2 LED Beacon Component Nominal Current: |
D2xB1X10 10J Xenon Beacon Component Nominal Current: |
D2xB1X05 5J Xenon Beacon Component Nominal Current: |
D2xS1 Alarm Horn Sounder Component Nominal Current: |
---|---|---|---|---|---|
24Vdc | 99.5mA | 560mA | 275mA | 313mA | |
115-120Vac | 50/60Hz | 68mA | 185mA | 80mA | 90mA |
220-230Vac | 50/60Hz | 70mA | 107mA | 30mA | 52mA |
Part Code: | Ident.: | Description: |
---|---|---|
Product type: | D2xC3 | Alarm Bar Xenon Strobe or LED Beacons with Alarm Horn Sounder |
Junction box & back plate: | N1 J1 |
No junction box required With D2xJ1 junction box |
Beacon Type (Add code for each Beacon required) |
1Y 2Y 3Y 4Y 5Y Y=Colour: Note: |
D2xB1X05 5 Joule Xenon Strobe Beacon D2xB1X10 10 Joule Xenon Strobe Beacon D2xB1LD2 LED Beacon A: Amber B: Blue C: Clear G: Green M: Magenta R: Red Y: Yellow D2xB1LD2 with AC supply voltage only available in first beacon position with J1 Junction Box option |
Alarm horn: | S1 | D2xS1 Alarm Horn Sounder |
Voltage: | AC115 AC230 DC024 |
115-120Vac 50/60Hz 220-230Vac 50/60Hz 24Vdc |
Cable entries: [e] | A B C D E F G |
2 x M20x1.5 2 × 1/2” NPT 2 × 3/4" NPT – adaptors 2 x M25x1.5 – adaptors 1 × 1/2” NPT 1 × 3/4" NPT – adaptor 1 x M25x1.5 – adaptor |
Stopping plug/Adaptor material: [m] | B N S |
Brass Nickel Plated Stainless Steel |
Guard/Tag material: [s] | 1 3 5 |
316 St/St Guard & 316 Equipment Tag 316 St/St Guard & 316 Equip. Tag & Duty Labels 316 St/St Guard & 316 Equip. Tag & Duty Labels attached by steel wire |
Product version: [v] | A | UL, cUL, ULC, IECEx & ATEX |
Product option: [o] | 1 2 3 4 5 6 W X Note: |
Standard Wiring (Positive stage switching) Independent Wiring (Positive stage switching) Alt. Standard Wiring (Negative stage switching) Independent Wiring (Negative stage switching) Beacons & Sounder Linked w/ Line Monitoring Independent Wiring w/ Line Monitoring Special Wiring Custom Configuration Options are product specific, please review wiring drawings |
Enclosure colour: [x] | R G |
Red Grey |
Example: | D2xC3 J1 5G 5A 5R S1 DC024 B N 1 A 1 G D2xC3 Stack with a D2xJ1 junction box and 3 x D2xB1LD2 LED beacons with green, amber and red lenses, D2xS1 alarm horn sounder, 2 × 1/2" NPT entries with nickel plated brass stopping plugs and a grey enclosure |
|
NOTE: | Assemblies with 115Vac or 230Vac supply voltage requiring a D2xB1LD2 LED beacon in the first position must also select the ‘J1’ junction box option. Stacks of 4 or more beacons plus an alarm horn sounder are available as custom assemblies – contact E2S for further details. |