Datasheet | Datasheet.pdf |
Installation Manual | D207-01-001-IS_Issue_5__MA1_MA2_.pdf |
-Install manual Telephone-Relay version [T] | D207-01-681-IS_Issue_1__MA1-T_MA2-T_.pdf |
Russian EAC Declaration of Conformity | _RU_-GB.01.B.57505-21__14.10.2026_.pdf |
Russian Maritime register | 19.00193.278.pdf |
Ingress Protection certificate | CoTC_104520_Issue_2_M.pdf |
Declaration of Conformity | DC-028_Issue_J_Marine.pdf |
SIL Certificate: Product version [A] | T1072-215-2_SIL2_SIL1_2H__D1xS_D1xC_STExS_STExC_GNExS_A112N_AL112N_A121_AL121_MA_.pdf |
2D drawing (PDF) | D207-05-101_Issue_A.pdf |
2D drawing (DWG) | D207-05-101_Issue_A.dwg |
3D drawing (STEP) | D207-05-101-3D_Issue_A.STEP |
Wiring Schematic DC voltage | D207-06-001_Issue_D.pdf |
Wiring Schematic AC voltage | D207-06-005_Issue_B__MA1_2-AC_.pdf |
Pole Mount & Sun Shade Drawing | D217-05-073_Issue_1__MA2F_ML25F_.pdf |
Hi-res product image 1 (TIFF) | 2-21-200_MA2F-R.jpg |
Hi-res product image 2 (TIFF) | 2-21-200_MA2F-G.jpg |
Maximum output: | High power level: 123dB(A) @ 1 m +/- 3dB [114dB(A) @ 10ft/3m +/- 3dB] Default power level: 120dB(A) @ 1 m +/- 3dB [111dB(A) @ 10ft/3m +/- 3dB] |
Nominal output: | High power level: 120dB(A) @ 1m +/- 3dB [111dB(A) @ 10ft/3m] +/- 3dB Default power level: 117dB(A) @ 1m +/- 3dB [108dB(A) @ 10ft/3m] +/- 3dB |
No. of tones: | 64 (UKOOA / PFEER compliant) |
No. of stages: | 4 |
Volume control: | Full range control |
Effective range: | High power level: 320m/1050ft @ 1KHz Default power level: 214m/702ft @ 1KHz |
Voltages DC: | 10-60V dc High voltage DC option available |
Voltages AC: | 100-240V ac 50/60Hz |
In rush: | 815mA within 4.0ms @ 24Vdc |
Stage switching: | Negative, positive, voltage free |
Line monitoring: | Diode polarized for use in supervised circuits |
Safety Integrity Level: | SIL1 and SIL2 Route 2H IEC61508 (2010) |
Ingress protection: | IP66 & IP67 Type 4/4X/13 |
Enclosure material: | High impact UL94 V0 & 5VA FR ABS |
Enclosure colour: | Grey or Red |
Cable entries: | 2 x M20; 1 x M20 & 1 × 1/2"NPT; 2 × 1/2"NPT supplied with blanking plug |
Terminals: | 0.5 – 2.5mm² (20-14 AWG) |
Operating temp: | -40 to +66°C [-40° to +151°F] |
Storage temp: | -40 to +70°C [-40° to +158°F] |
Relative humidity: | 99% |
MTBF DC: | 93.92 years / 822,706 hours – MIL 217 |
MTBF AC: | 46.66 years / 408,508 hours – MIL 217 |
Weight DC: | 2.75kg/6.0Ibs |
Weight AC: | 3.25kg/7.2Ibs |
Product Version: | Nominal Voltage: | Voltage Range: | Default Power Level Current: |
High Power Level Current: |
---|---|---|---|---|
DC024 | 12V dc 24V dc 48Vdc |
10-60V dc | 376mA 391mA 223mA |
440mA 888mA 453mA |
AC230 | 115Vac 50/60Hz 230V ac 50/60Hz |
100-240V ac | 173mA 107mA |
340mA 212mA |
Variable: | Identifier: | Description: |
---|---|---|
Product type: | MA2 | Alarm horn sounder |
Flare type: | F | Flare re-entrant horn |
Voltage: | DC024 AC230 |
10-60V dc 100-240V ac 50/60Hz |
Cable entries: [e] | A B C |
M20x1.5 & ½” NPT M20x1.5 & M20x1.5 (Default) ½” NPT & ½” NPT |
Stopping plug material: [m] | N | Nylon |
Bracket: [s] | 1 3 |
316 (A4) Stainless Steel 316 (A4) Stainless Steel with Equipment tag |
Product version: [v] |
A T |
CE, EAC, RMRS, SIL1 & SIL2 Telephone/Relay Initiate – CE, EAC, RMRS |
Product option: [o] |
1 Z X Y K V |
Standard product Custom alarm tone software – contact E2S Custom configuration – contact E2S Stage control Config. 4 Stage control Config. 5 (DC) and Config. 2 (AC) Stage control Config. 6 |
Enclosure colour: [x] | G R S |
Grey Red Special colour – contact E2S |
Accessories: SP65-0001-A4 SP65-0003-A4 |
Pole Mount Bracket Kit St/St 316 (A4) Sunshade – St/St 316 (A4) |
|
Alarm stage control: | ||
Please review the installation manual and wiring schematics for remote stage control and EOL resistor monitoring configuration options: | ||
Config. 1 [DC]: | Factory default. Common negative, positive switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only | |
Config. 2 [DC]: | User setting. Common positive, negative switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only | |
Config. 3 [DC]: | User setting. Common negative, positive switching activation of Alarm Stages 1 & 2 with EOL on both stages. Reverse polarity monitoring | |
Config. 4 [DC]: | Product option ‘Y’. Independent activation of Alarm Stages 1 & 2 with EOL on both stages. Forward polarity monitoring | |
Config. 5 [DC]: | Product option ‘K’. Horn continuously powered. Voltage free activation of up to 3 alarm stages | |
Config. 6 [DC]: | Product option ‘V’. Independent activation of up to 4 Alarm Stages with EOL on all stages. Forward polarity monitoring | |
Config. 1 [AC]: | Factory default. Up to 4 Alarm Stages. Stage 1 activated at power on. Stages 2, 3 and 4 via volt free contacts | |
Config. 2 [AC]: | Product option ‘K’. Horn continuously powered. Voltage free activation of up to 3 alarm stages |