Maximum output: | High power level: 127dB(A) @ 1 m +/- 3dB [118dB(A) @ 10ft/3m +/- 3dB] Medium power level: 122dB(A) @ 1 m +/- 3dB [113dB(A) @ 10ft/3m +/- 3dB] |
Nominal output: | High power level: 124dB(A) @ 1m +/- 3dB [115dB(A) @ 10ft/3m] +/- 3dB Medium power level: 119dB(A) @ 1m +/- 3dB [110dB(A) @ 10ft/3m] +/- 3dB |
No. of tones: | 64 (UKOOA / PFEER compliant) |
No. of stages: | 4 |
Volume control: | Full range |
Effective range: | >350m/1148ft @ 1KHz |
Voltages DC: | 24Vdc (11.5-54Vdc) |
Voltages AC: | 230Vac (100-240Vac) |
In-rush: | 815mA within 4ms @ 24Vdc |
Stage switching: | DC units: positive or negative AC units: common supply line |
Safety Integrity Level: | SIL1 and SIL2 Route 2H IEC61508 (2010) |
Ingress protection: | EN60529: IP66/67 |
Enclosure material: | 316L Stainless Steel |
Enclosure colour: | Red |
Enclosure finish: | Chromate & powder coated finish |
Cable entries: | 3 x M20x1.5mm Stopping plugs included |
Stopping plugs: | Stainless Steel |
Terminals: | 0.5 – 2.5mm² (20-14 AWG) Pluggable & duplicated terminals |
Line monitoring: | Diode polarized for use in supervised circuits Blocking diode for reverse polarity monitoring |
Ground/Earth stud: | M5 |
Line monitoring: | Blocking diode included EOL Min. 500 Ohm 2W, or 3k3 Ohm 0.5W resistor or diode (DC versions) can be fitted |
Enclosure volume: | <2 litres |
Installation temp: | -50° to +70°C (-58°F to +158°F) |
Storage temp: | -50° to +70°C (-58°F to +158°F) |
Relative humidity: | 99% |
MTBF DC: | 93.92 years / 822,706 hours – MIL 217 |
MTBF AC: | 46.66 years / 408,508 hours – MIL 217 |
Weight: | 6.25kg/13.75lbs |
Nominal Voltage: |
Voltage range: |
Medium Power current: |
Medium Power Max. Current: |
High Power current: |
High Power Max. Current: |
In-rush: |
---|---|---|---|---|---|---|
12Vdc | 11.5-54Vdc | 289mA | 324mA | 356mA | 740mA | - |
24Vdc | 11.5-54Vdc | 324mA | 324mA | 740mA | 740mA | 815mA <4ms |
48Vdc | 11.5-54Vdc | 195mA | 324mA | 391mA | 740mA | - |
115Vac 50/60Hz | 100-240V ac | 125mA | 138mA | 282mA | 325mA | - |
230Vac 50/60Hz | 100-240V ac | 78mA | 138mA | 167mA | 325mA | - |
Part Code: | Identifier: | Description: |
---|---|---|
Product type: | STExS2 | STExS2 alarm horn sounder |
Horn type: | H | High SPL flare re-entrant horn |
Voltage: | DC024 AC230 |
11.5-54Vdc 100-240Vac |
Cable entries:[e] | A B C D E F G |
3 x M20x1.5mm 2 × 1/2" NPT – adaptors 2 × 3/4" NPT – adaptors 2 x M25x1.5mm – adaptors 1 × 1/2" NPT – adaptor 1 × 3/4" NPT – adaptor 1 x M25x1.5mm – adaptor |
Stopping plug/ adaptor material: [m] |
S | Stainless steel |
Bracket material: [s] | 1 3 |
A4 316 Stainless Steel A4 316 St/St with Equip. Tag |
Product version: [v] | A S T |
UL, cUL, ULC, IECEx, ATEX, DNV, Ex EAC, INMETRO SIL1 & SIL2 Route 2H UL, cUL, ULC, IECEx, ATEX, Ex EAC INMETRO SIL2 Route 1H with diagnostics SFF: >99% IECEx, ATEX, Ex EAC, INMETRO – Telephone/Relay initiate |
Product option: [o] | 1 Z X Y K V |
Standard product Custom alarm tone software – contact E2S Custom configuration – contact E2S Stage control Config. 4 Stage control Config. 5 (DC) and Config. 2 (AC) Stage control Config. 6 |
Enclosure colour: [x] | R S |
Red Special – contact E2S for alternative enclosure colours |
Accessories: | ||
SP65-0001-A4 | Pole Mount Bracket Kit St/St A4 (316) |
Alarm stage control: | ||
---|---|---|
Please review the installation manual and wiring schematics for remote stage control and EOL resistor monitoring configuration options: | ||
Config. 1 [DC]: | Factory default. Common negative, positive switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only | |
Config. 2 [DC]: | User setting. Common positive, negative switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only | |
Config. 3 [DC]: | User setting. Common negative, positive switching activation of Alarm Stages 1 & 2 with EOL on both stages. Reverse polarity monitoring | |
Config. 4 [DC]: | Product option ‘Y’. Independent activation of Alarm Stages 1 & 2 with EOL on both stages. Forward polarity monitoring | |
Config. 5 [DC]: | Product option ‘K’. Horn continuously powered. Voltage free activation of up to 3 alarm stages | |
Config. 6 [DC]: | Product option ‘V’. Independent activation of up to 4 Alarm Stages with EOL on all stages. Forward polarity monitoring | |
Config. 1 [AC]: | Factory default. Up to 4 Alarm Stages. Stage 1 activated at power on. Stages 2, 3 and 4 via volt free contacts | |
Config. 2 [AC]: | Product option ‘K’. Horn continuously powered. Voltage free activation of up to 3 alarm stages |