GNExCP7-BG Break Glass Manual Call Point 1-24-150

Product image
Product Image
Product Image
The explosion proof GNExCP7-BG break glass Ex d manual call points feature a robust GRP enclosure with a 316 stainless steel mechanism and IP66/67 rating – manufactured for the harshest of hazardous environments.
Request a quote for this product
Type
Switch type
Terminals
Lift flap
Cable entries
Stopping plug/adaptor material
Duty label & equipment tag
Product version
Product option
Enclosure colour
LED indicator
E.O.L module
Series module
Part Number:
GNExCP7
Request Price or enquire about this product
Enquire about
Break Glass Manual Call Point

New Product

  • Ex d explosion proof call point
  • Globally approved UL, cUL, IECEx, ATEX, UKCA
  • GRP enclosure anti-static UV stable
  • 316 stainless steel mechanism
  • Optional stainless steel lift flap
  • Triple cable entries
  • Available with addressable modules

Description

Globally approved to IECEx, ATEX, UL and cUL standard for all Zone 1, 2, 21 & 22 and Class I/II Div 2 installations. Can also be specified for applications requiring compliance to the UL38 standard for Manual Signaling Boxes for Fire Alarm Systems or ULC-S528 Manual Stations For Fire Alarm Systems. Available with DIN rail terminals or the innovative E2S termination board with dedicated connections for field installed EOL and/or series devices. SIL 2 compliant to IEC 61508 (2010).

Downloads

Datasheet Datasheet.pdf
A version installation D202-01-011-IS_Issue_3__GNExCP7-BG_.pdf
F version installation D202-01-001-IS_Issue_2__GNExCP7-BG-F_.pdf
INMETRO Installation Manual D202-00-011-IS-PRT_Issue_3.pdf
IECEx certificate IECEx_ULD_19.0007_03_GNExCP7.pdf
ATEX certificate DEMKO_19_ATEX_2101X_Rev._3_GNExCP7.pdf
UL certificate of compliance UL_CoC_E482536_E513632_E508420_GNExCP7.pdf
UKCA Certificate UL21UKEX2134X_Rev._2_GNExCP7.pdf
INMETRO certificate IEx_23.0091X_R0_GNExCP7.pdf
DNV Type Approval TAA000034V_1.pdf
ECAS Ex Approval 24-06-114470_E24-06-118037_NB0007_GNExCP7.pdf
Ingress Protection certificate TL23105B_GNExCP7-BG.pdf
Declaration of Conformity DC-078_Issue_F_GNExCP7.pdf
SIL2 Certificate T916-133_2_SIL_2_STExCP8_GNExCP7_WP7.pdf
Declaration of Conformity UKCA DC-099_Issue_B_GNExCP7_UKCA.pdf
2D drawing (PDF) D202-05-001_Issue_C.pdf
2D drawing (DWG) D202-05-001_Issue_C.DWG
3D drawing (STEP) D202-05-001-3D_Issue_1.STEP
Wiring Schematics - PCB Terminals D202-06-212_Issue_1.pdf
Wiring Schematics - DIN Rail Terminals D202-06-211_Issue_6.pdf
Nameplate Drawing D202-09-001-011_051_GNExCP7-BG.pdf
Equipment Tag Drawing D254-00-111_Issue_1.pdf
Duty Label Drawing D254-00-011_Issue_1.pdf
Pole Mount & Sun Shade Drawing D217-05-331_Issue_2__GNExCP7_BG_.pdf
Product image with LED module GNExCP7-BG-Red-01-L.png

Features

  • Corrosion proof GRP enclosure, anti-static & UV stable
  • Ingress protection IP66/67/68, 4/4X/3R/13
  • Single or double switch (SPCO/DPCO)
  • 316 (A4) stainless steel mechanism
  • Optional stainless steel lift flap
  • 3 x cable entries, 2 x stopping plugs included
  • Available with addressable modules
  • Optional LED indicator

Specification

GNExCP7-BG: Break Glass Manual Call Point
Temp. Range: -55°C to +60°C/+70°C
Switch: Sealed – IP67
Ingress protection: IP66/67/68 to EN/IEC 60529
4/4X/3R/13 to UL50E/NEMA250
Enclosure matl: GRP Glass Reinforced Polyester, anti-static & UV stable
Colour: Red
Other solid and striped colours available
Lift flap: Optional 316 stainless steel lift flap
Cable entries: 2 x M20x1.5 down facing and 1 x M20x1.5 side
Back box can be rotated to provide 2 x top facing and 1 x side entries
Cable entries adaptable to 1/2"NPT, 3/4"NPT & M25
Stopping plugs: 2 x Stopping plugs as standard
Brass, Nickel plated or Stainless Steel
Terminals: DIN rail 8 × 2.5mm² SAK2.5 or
Termination board featuring 6 × 2.5mm² terminals plus 4 x dedicated EOL & Series terminals
Earth: External M5 earth connection
Relative Humidity: R.H. 95% @ 20°C
MTBF: 479.6 years / 4,201,680 hours ​- MIL 217
Weight: 2.1Kg/4.63Ibs

Voltage Range:

Max input Current:

Limitations for EOL / Series Resistors:
250Vac Max 3.33A max not permitted
48Vdc Max 1.0A max min. 2.2kOhm
24Vdc Max 3.0A max min. 470 Ohm
EOL and Series Diode Values:
xxx: Zener Value Max. current supply permitted
3V3 3.3V Diode 230mA
4V7 4.7V Diode 162mA
5V1 5.1V Diode 149mA
5V6 5.6V Diode 136mA
6V2 6.2V Diode 122mA
6V8 6.8V Diode 112mA
10V 10V Diode 76mA
12V 12V Diode 63mA


Spares:
SP70-0001
SP70-0040
Spare Break Glass – Box of 50
Spare GNExCP7-BG Test Key
Accessories:
SP65-0001-A4
SP65-0002-A4
Pole Mount Bracket Kit St/St A4 (316)
Sunshade – St/St A4 (316)

Part Codes

Version: Part reference: Description:
Product type: GNExCP7BG Break Glass Manual Call Point
Switch type: [s] S
D
SPCO/SPDT
DPCO/DPDT
Terminals: [t] D
X
P
DIN Rail 8 × SAK2.5
Addressable module – select below
Termination board: 6 × 2.5mm² terminals plus 4 × EOL & Series terminals
Lift flap: [l] N
L
No lift flap
Stainless steel lift flap
Cable entries:[e] A
B
C
D
E
F
G
3 x M20x1.5mm
2 × 1/2" NPT – adaptors
2 × 3/4" NPT – adaptors
2 x M25x1.5mm – adaptors
1 × 1/2" NPT – adaptor
1 × 3/4" NPT – adaptor
1 x M25x1.5mm – adaptor
Stopping plug/
adaptor material: [m]
B
P
S
Brass
Nickel Plated Brass
Stainless Steel
Duty label/Equipment tag: [d]: 1
2
3
4
5
6
7
No Duty label, no Equip. tag
Duty label Stainless Steel
Duty label St/St + Equip. tag
Duty label Metalised Polyester
Duty label M. Poly. + Equip. tag
Equip. tag only
Special label requirement
Product version:
[v]
A
F

H
Z
M
C
P
E
S
D
L
UL, cUL, IECEx, ATEX, INMETRO & PESO
UL38 & ULC-S528 Fire
UL, cUL, ULC, IECEx, ATEX, INMETRO & PESO
Honeywell TC809B1008 module IECEx, ATEX, INMETRO
Ziton A45E-2 module IECEx, ATEX, INMETRO
Johnson Controls MIM800 module IECEx, ATEX, INMETRO
Hochiki CHQ-CP2 monitor IECEx, ATEX, INMETRO
Apollo XP95 mini module IECEx, ATEX, INMETRO
Consilium IC10 module IECEx, ATEX, INMETRO
Siemens XTRI-M module IECEx, ATEX, INMETRO
Securiton SDI 82X-I module IECEx, ATEX, INMETRO
Simplex 4090-9051 Supervised IAM IECEx, ATEX, INMETRO
Product option: [o] 1
W
2
Y
P
V
Note:
Standard product
Alternate EOL & series wiring
Duplicated EOL and/or series devices
Duplicated EOL and series – alternate wiring
Parallel wiring with or without EOL/series
Parallel with EOL and series alternate wiring
Duplicated EOL/series and Parallel wiring only available with switch type ‘D’
Enclosure colour: [x] R
B
N
Y
V
S
K
M
Z
Red (F version mandatory)
Blue
Green
Yellow
Red/White
Yellow/Black
Black
Magenta
Red/Black
LED indicator: [u] N
L
C
No LED required (F version mandatory)
LED with 1.5K ballast resistor
LED without ballast resistor
E.O.L.Module: [e]
optional
ExxxR
ED1
ExxxZ
Resistor value in Ohms e.g. E470R = 470 Ohm
Diode IN4007 = ED1
Zener diode e.g. E5V1Z = 5.1V
Series Module: [s]
optional
SxxxR
SD1
SxxxZ
Resistor value in Ohms e.g. S1K5R = 1.5K Ohm
Diode IN4007 = SD1
Zener diode e.g. S5V1Z = 5.1V

Approvals

  • UL/cUL certificate: 20190604-E482536, 20200224-E513632
  • IECEx certificate: IECEx ULD 19.0007X
  • ATEX certificate: DEMKO 19 ATEX 2101X
  • UKCA certificate: UL21UKEX2134X
  • INMETRO certificate IEx 23.0091X
  • DNV certificate TAA000034V
  • SIL 2 compliant to IEC 61508 (2010)

Coding

  • NEC / CEC:
    Class I Div 2 Group ABCD T5 Ta -55°C to +70°C
    Class I Div 2 Group ABCD T6 Ta -55°C to +60°C
    Class II Div 2 Group FG T4 Ta -55°C to +60°C
    Class III Div 1 & 2 Ta -55°C to +60°C
  • NEC:
    Class I Zone 1 AEx db IIC T5 Gb (Ta -55°C to +70°C)
    Class I Zone 1 AEx db IIC T6 Gb (Ta -55°C to +60°C)
    Zone 21 AEx tb IIIC T135°C Db (Ta -55°C to +70°C)
    Zone 21 AEx tb IIIC T125°C Db (Ta -55°C to +60°C)
  • CEC:
    Class I Zone 1 Ex db IIC T5 Gb X (Ta -55°C to +70°C)
    Class I Zone 1 Ex db IIC T6 Gb X (Ta -55°C to +60°C)
    Zone 21 Ex tb IIIC T135°C Db (Ta -55°C to +70°C)
  • IECEx & ATEX:
    II 2G Ex db IIC T5 Gb Ta. -55 to +70°C
    II 2G Ex db IIC T6 Gb Ta. -55 to +65°C
    II 2D Ex tb IIIC T90°C Db Ta. -55° to +70°C
    See product manual for full product specific coding.

Note

F version only available with Duty label option 2 or 3. Mandatory duty label: “FIRE/FEU”
F version only available with Red enclosure
F version not available with LED indicator
All trademarks are the property of their respective owners

Upcoming Events

Fse (4)
Cafaa%202020%20final%20cmyk
Logo
Nfpa conference expo