Datasheet | Datasheet.pdf |
Installation Manual | D225-01-001-IS_Issue_3__D1xC4_.pdf |
IECEx certificate | IECEx_ULD_19.0006X_001-19.0008X_002_D1xP_C.pdf |
ATEX certificate | DEMKO_19_ATEX_2009X_Iss_1-19_ATEX_2141X_Iss_2_D1xP_C.pdf |
UL certificate of compliance | UL_CoC_-_E245313-E230764_D1x.pdf |
CSFM Listing | CSFM_Listing_2279-0506_D1xS__D1xC_2025.pdf |
UKCA Certificate | UL21UKEX2130X_Rev_0-2132X_Rev_1_D1x.pdf |
2D drawing (PDF) | D225-05-001_Issue_2.pdf |
2D drawing (DWG) | D225-05-001_Issue_2.DWG |
3D drawing (STEP) | D225-05-001_Issue_1_S1F.STEP |
Wiring Schematic | D225-06-001_Issue_3.pdf |
Equipment Tag Drawing | D254-00-111_Issue_1.pdf |
Duty Label Drawing | D254-00-041_Issue_1.pdf |
Hi-res product image 1 (TIFF) | D1xC4-R-R-C.tif |
Hi-res product image 2 (TIFF) | D1xC4-G-R.tif |
Beacon Option: | D1xB2X05/10/15/21 Xenon Strobe Beacons |
---|---|
Product data: | D1xB2X05: www.e2s.com/1-21-202 D1xB2X10: www.e2s.com/1-21-203 D1xB2X15: www.e2s.com/1-21-204 D1xB2X21: www.e2s.com/1-21-205 |
Flash rate: | DC: 1Hz (60fpm), 1.5Hz (90fpm) & double flash AC: 1Hz (60fpm) |
Eff. Intensity cd: | D1xB2X05: 156.65cd D1xB2X10: 645.21cd D1xB2X15: 731.71cd D1xB2X21: 1250.66cd [Measured ref to I.E.S] |
Beacon Option: |
D1xB2LD2 LED Beacon |
Product data: | D1xB2LD2: www.e2s.com/1-21-206 |
Source: | Array of 4 x High Power Cree® LED’s |
Modes: | 1Hz flash (60 fpm), 1.5Hz (90 fpm), 2Hz (120 fpm) Double strike flash, Triple strike flash High Power Steady, Low Power Steady |
Eff. Intensity cd: | 174 cd – High Power Steady |
Eff. Intensity cd: | 338 cd – 1Hz flash |
Alarm Horn: |
D1xS1F/S1R/S2F/S2H Alarm Horn Sounders |
Product data: | D1xS1F: www.e2s.com/1-22-140 D1xS1R: www.e2s.com/1-22-145 D1xS2F: www.e2s.com/1-22-150 D1xS2H: www.e2s.com/1-22-155 |
Max. SPL: | D1xS1F: 115dB(A) @ 1m [106dB(A) @ 10ft] D1xS1R: 110dB(A) @ 1m [101dB(A) @ 10ft] D1xS2F: 123dB(A) @ 1m [114dB(A) @ 10ft] D1xS2H: 128dB(A) @ 1m [119dB(A) @ 10ft] |
Nom. SPL +/- 3dB: | D1xS1F: 110dB(A) @ 1m [101dB(A) @ 10ft] D1xS1R: 105dB(A) @ 1m [96dB(A) @ 10ft] D1xS2F: 118dB(A) @ 1m [109dB(A) @ 10ft] D1xS2H: 126dB(A) @ 1m [117dB(A) @ 10ft] |
No. of tones: | 64 (UKOOA / PFEER compliant) |
No. of stages: | 4 – Positive or Negative stage switching |
Volume control: | Full range |
Junction Box: |
D1xJ2 Ex d Junction Box |
Product data: | D1xJ2: www.e2s.com/1-25-025 |
Terminals: | DIN Rail 12 × AKZ 2.5, Earth 4 × AKE 2.5 |
General information: | Common component features: |
Mounting: | Pole mount kit included |
Ingress protection: | EN60529: IP66/67, UL50E / NEMA250: 4 / 4X / 3R / 13 |
Enclosure material: | Marine grade aluminium LM6 – copper free Chromated & powder coated – corrosion proof |
Enclosure colour: | Red or Grey, custom colours available on request |
Lens material: | Borosilicate glass dome & PC colour filter |
Lens guard: | 316 (A4) Stainless Steel dome guard as standard |
Cable entries: | 1 x M20x1.5 and 1 × 3/4"NPT – thread adaptors available |
Stopping plugs: | Brass/Nickel Plated/Stainless Steel plugs included |
Line monitoring: | Blocking diode included. EOL can be factory fitted |
Installation temp: | -55 to +75/80/85°C [-67° to +167/176/185°F] |
Storage temp: | -55 to +85°C [-67° to +185°F] |
Relative humidity: | 95% – Additional tropicalisation is recommended for applications where both high relative humidity and high ambient temperatures exist |
Voltage: | D1xB2LD2 LED Beacon Component Nominal/Max. Current: |
D1xB2X05 5J Xenon Beacon Component Nominal/Max. Current: |
D1xB2X10 10J Xenon Beacon Component Nominal/Max. Current: |
D1xB2X15 15J Xenon Beacon Component Nominal/Max. Current: |
D1xB2X21 21J Xenon Beacon Component Nominal/Max. Current: |
D1xS1R or F Alarm Horn Sounder Component Nominal/Max. Current: |
D1xS2F Alarm Horn Sounder Component Nominal/Max. Current: |
D1xS2H Alarm Horn Sounder Component Nominal/Max. Current: |
---|---|---|---|---|---|---|---|---|
24V dc (20-28Vdc) |
110mA/500mA | 295mA/350mA | 605mA/710mA | 853mA/920mA | 1130mA/1240mA | 185mA/221mA | 324mA/324mA | 740mA/740mA |
115-120Vac 50/60Hz | 90mA/180mA | 140mA/200mA | 220mA/300mA | 310mA/420mA | 500mA/530mA | 73mA/80mA | 125mA/138mA | 282mA/325mA |
220-230Vac 50/60Hz | 45mA/100mA | 70mA/100mA | 130mA/180mA | 170mA/230mA | 195mA/270mA | 48mA/80mA | 78mA/138mA | 167mA/325mA |
Part Code: | Identifier: | Description: |
---|---|---|
Product type: | D1xC4 | Integrated Alarm Bar of LED and/or Xenon Strobe Beacons with Alarm Horn Sounder |
Junction box & back plate: | J2 | Junction box with 12 × SAK 2.5 DIN rail terminals |
Beacon 1 Beacon 2 |
For each beacon select the numeric identifier plus colour character as follows: 1 = D1xB2X05 5J Xenon Beacon 2 = D1xB2X10 10J Xenon Beacon 3 = D1xB2X15 15J Xenon Beacon 4 = D1xB2X21 21J Xenon Beacon 5 = D2xB1LD2 LED Beacon A=Amber, B=Blue, C=Clear, G=Green, M=Magenta, R=Red, Y=Yellow e.g. 5R = D1xB2LD2 LED Beacon with Red lens |
|
Alarm horn: | S1R S1F S2F S2H |
D1xS1R 110dB(A) Radial Horn Alarm Sounder D1xS1F 115dB(A) Flare Horn Alarm Sounder D1xS2F 123dB(A) Flare Horn Alarm Sounder D1xS2H 128dB(A) Flare Horn Alarm Sounder |
Voltage: | AC115 AC230 DC024 |
115-120Vac 50/60Hz 220-230Vac 50/60Hz 24Vdc (20-28Vdc) |
Cable entries: [e] | A B C D |
1 x M20x1.5mm – adaptor 1 × 1/2" NPT – adaptor 1 × 3/4" NPT – default 1 x M25x1.5mm – adaptor |
Stopping plug/ adaptor material: [m] |
B N S |
Brass Nickel Plated Stainless Steel |
Guard material: [s] | 1 3 |
A4 316 Stainless Steel with Equip. Tag A4 316 St/St with Equip. Tag & Duty Labels |
Product version: [v] | A C S |
IECEx/ATEX/UL/cUL Class I Zone 1 UL/cUL Class Div 1 SIL2/IECEx/ATEX/UL/cUL Class I Zone 1 |
Product option: [o] |
1 T Z W X V |
Standard product Tropicalised Custom alarm tone software – contact E2S Custom wiring – contact E2S Custom configuration – contact E2S Alarm horn stage ctrl Config. 6 Independent Stage Activation with Line Monitoring for 3 or 4 Alarm Stages |
Enclosure colour: [x] | G R |
Grey Red |
Example: | D1xC4 J2 5G 5A 5R S1R DC024 B N 1 A 1 G D1xC4 alarm bar with a junction box with DIN rail terminals and 2 x D1xB2LD2 LED beacons with Blue and Yellow lenses, D1xS1R alarm horn sounder, 1 × 3/4" NPT entries with nickel plated brass stopping plugs in a grey enclosure |
D1xB2LD2 | LED Beacon component: |
---|---|
NEC / CEC: | Class I Div 1 Group ABCD T5 Ta -55°C to +80°C Class I Div 1 Group ABCD T6 Ta -55°C to +75°C Class II Div 1 Group EFG T4 Ta -55°C to +80°C |
NEC: | Class I Zone 1 AEx db IIC T5 Ta -55°C to +80°C Class I Zone 1 AEx db IIC T6 Ta -55°C to +70°C Zone 21 AEx tb IIIC T100°C Ta -55°C to +80°C |
CEC: | Ex db IIC T4 Ta -55°C to +80°C Ex db IIC T5 Ta -55°C to +70°C Ex tb IIIC T100°C Ta -55°C to +80°C |
IECEx & ATEX: | II 2G Ex db IIC T5 Gb Ta -55°C to +80°C II 2G Ex db IIC T6 Gb Ta -55°C to +70°C II 2D Ex tb IIIC T100°C Db Ta -55°C to +80°C |
D1xB2X05 | 5J Xenon Beacon component: |
NEC / CEC: | Class I Div 1 Group ABCD T5 Ta -55°C to +80°C (AC: T4A +70°C) Class I Div 1 Group ABCD T6 Ta -55°C to +70°C (AC: +40°C) Class II Div 1 Group EFG T5 Ta -55°C to +80°C (AC: T4 +40°C) Class III Div 1 Ta -55°C to +80°C (AC: +40°C) |
NEC: | Class I Zone 1 AEx db IIC T4 Ta -55°C to +80°C (AC: +70°C) Class I Zone 1 AEx db IIC T5 Ta -55°C to +75°C (AC: +50°C) Class I Zone 1 AEx db IIC T6 Ta -55°C to +60°C (DC only) Zone 21 AEx tb IIIC T99°C Ta -55°C to +80°C (AC: T153°C +70°C) |
CEC: | Ex db IIC T4 Ta -55°C to +80°C (AC: +70°C) Ex db IIC T5 Ta -55°C to +75°C (AC: +50°C) Ex db IIC T6 Ta -55°C to +60°C (DC only) Ex tb IIIC T99°C Ta -55°C to +80°C (AC: T153°C +70°C) |
IECEx & ATEX: | II 2G Ex db IIC T4 Gb Ta -55°C to +80°C (AC: +70°C) II 2G Ex db IIC T5 Gb Ta -55°C to +75°C (AC: +50°C) II 2G Ex db IIC T6 Gb Ta -55°C to +60°C (DC only) II 2D Ex tb IIIC T104°C Db Ta -55°C to +80°C (AC: T116°C+70°C) |
D1xB2X10 | 10J Xenon Beacon component: |
NEC / CEC: | Class I Div 1 Group ABCD T4 Ta -55°C to +80°C (AC: +70°C) Class I Div 1 Group ABCD T4A Ta -55°C to +70°C (AC: +55°C) Class I Div 1 Group ABCD T5 Ta -55°C to +50°C Class II Div 1 Group EFG T4 Ta -55°C to +80°C (AC: +40°C) Class II Div 1 Group EFG T4A Ta -55°C to +65°C / T5 to +45°C Class III Div 1 Ta -55°C to +80°C (AC: +40°C) |
NEC: | Class I Zone 1 AEx db IIC T4 Ta -55°C to +80°C (AC: +65°C) T5 to +45°C Class I Zone 1 AEx db IIC T5 Ta -55°C to +45°C Zone 21 AEx tb IIIC T132°C Ta -55°C to +80°C (AC: T153°C +70°C) |
CEC: | Ex db IIC T4 Ta -55°C to +80°C (AC: +65°C) T5 to +45°C Ex tb IIIC T132°C Ta -55°C to +80°C (AC: T153°C +70°C) |
IECEx & ATEX: | II 2G Ex db IIC T4 Gb Ta -55°C to +80°C (AC: +65°C) T5 to +45°C II 2D Ex tb IIIC T135°C Db Ta -55°C to +80°C (AC: T139°C +70°C) |
D1xB2X15 | 15J Xenon Beacon component: |
NEC / CEC: | Class I Div 1 Group ABCD T3C Ta -55°C to +80°C (DC only) Class I Div 1 Group ABCD T4 Ta -55°C to +55°C (AC: T4A +55°C) Class II Div 1 Group EFG T4 Ta -55°C to +80°C (AC: +40°C) Class III Div 1 Ta -55°C to +80°C (AC: +40°C) |
NEC: | Class I Zone 1 AEx db IIC T3 Ta -55°C to +80°C (AC: +65°C) Class I Zone 1 AEx db IIC T4 Ta -55°C to +65°C Zone 21 AEx tb IIIC T132°C Ta -55°C to +80°C (AC: T153°C +70°C) |
CEC: | Ex db IIC T3 Ta -55°C to +80°C (AC: +70°C) Ex db IIC T4 Ta -55°C to +65°C Ex tb IIIC T132°C Ta -55°C to +80°C (AC: T153°C +70°C) |
IECEx & ATEX: | II 2G Ex db IIC T3 Gb Ta -55°C to +80°C (AC: +65°C) II 2G Ex db IIC T4 Gb Ta -55°C to +45°C II 2D Ex tb IIIC T146°C Db Ta -55°C to +80°C (AC: T139°C +70°C) |
D1xB2X21 | 21J Xenon Beacon component: |
NEC / CEC: | Class I Div 1 Group ABCD T3B Ta -55°C to +80°C (DC only) Class I Div 1 Group ABCD T3C Ta -55°C to +75°C (AC: +60°C) Class I Div 1 Group ABCD T4 Ta -55°C to +50°C (AC: T4 +55°C) Class II Div 1 Group EFG T3C Ta -55°C to +40°C (AC: T4) Class III Div 1 Ta -55°C to +80°C (AC: +40°C) |
NEC: | Class I Zone 1 AEx db IIC T3 Ta -55°C to +80°C (AC: +60°C) Class I Zone 1 AEx db IIC T4 Ta -55°C to +45°C (AC +50°C) Zone 21 AEx tb IIIC T181°C Ta -55°C to +80°C (AC: T153°C +60°C) |
CEC: | Ex db IIC T3 Ta -55°C to +80°C (AC: +60°C) Ex db IIC T4 Ta -55°C to +45°C (AC: +60°C) Ex tb IIIC T181°C Ta -55°C to +80°C (AC: T153°C +60°C) |
IECEx & ATEX: | II 2G Ex db IIC T3 Gb Ta -55°C to +80°C (AC: +60°C) II 2G Ex db IIC T4 Gb Ta -55°C to +45°C (AC: +50°C) II 2D Ex tb IIIC T169°C Db Ta -55°C to +80°C (AC: T141°C +60°C) |
D1xS1R & D1xS1F | Alarm horn sounder component: |
NEC / CEC: | Class I Div 1 ABCD T5 Ta -55°C to +85°C Class I Div 1 ABCD T6 Ta -55°C to +75°C |
NEC / CEC: | Class I Zone 1 IIC T5 Ta -55°C to +85°C Class I Zone 1 IIC T6 Ta -55°C to +75°C |
IECEx & ATEX: | II 2G Ex db IIC T5 Gb Ta -55°C to +75°C II 2G Ex db IIC T6 Gb Ta -55°C to +70°C II 2D Ex tb IIIC T82°C Db Ta ‐55°C to +75°C |
D1xS2F & D1xS2H | Alarm horn sounder component: |
NEC / CEC: | Class I Div 1 ABCD T4A Ta -55°C to +85°C Class I Div 1 ABCD T5 Ta -55°C to +80°C (T6 +65°C) |
NEC / CEC: | Class I Zone 1 IIC T4A Ta -55°C to +85°C Class I Zone 1 IIC T5 Ta -55°C to +75°C (T6 +65°C) |
IECEx & ATEX: | II 2G Ex db IIC T5 Gb Ta -55°C to +75°C II 2G Ex db IIC T6 Gb Ta -55°C to +60°C II 2D Ex tb IIIC T93°C Db Ta ‐55°C to +75°C |
D1xJ2 | Junction Box component: |
NEC / CEC: | Class I Div 1 Group ABCD T4A Ta -55°C to +80°C Class I Div 1 Group ABCD T5 Ta -55°C to +75°C Class I Div 1 Group ABCD T6 Ta -55°C to +60°C Class II Div 1 Group EFG T4A Ta -55°C to +80°C Class III Div 1 Ta -55°C to +80°C |
NEC: | Class I Zone 1 AEx db IIC T4 Ta -55°C to +80°C Class I Zone 1 AEx db IIC T5 Ta -55°C to +70°C Class I Zone 1 AEx db IIC T6 Ta -55°C to +55°C Zone 21 AEx tb IIIC T106°C Ta -55°C to +80°C |
CEC: | Ex db IIC T4 Ta -55°C to +80°C Ex db IIC T5 Ta -55°C to +70°C Ex db IIC T6 Ta -55°C to +55°CEx tb IIIC T106°C Ta -55°C to +80°C |
IECEx & ATEX: | II 2G Ex db IIC T4 Gb Ta -55°C to +80°C II 2G Ex db IIC T5 Gb Ta -55°C to +70°C II 2G Ex db IIC T6 Gb Ta -55°C to +55°C II 2D Ex tb IIIC T106°C Db Ta -55°C to +80°C |