Product finder
Product code
Application
Environment
Device
Category
Product
Type
Product finder

Find the right E2S product

Search

D1xC3 Xenon/LED & Horn Alarm Bar 1-26-080

Product image
Product Image
Product Image
The D1xC3 is an audio-visual explosion proof alarm bar with up to 4 Xenon strobe or LED beacons with a high output alarm horn warning signal. Approved to IECEx, ATEX, UL and cUL for Zone 1, 21 and Class I Zone 1 and 21 plus versions suitable for Class I Division 1. The robust marine grade, corrosion proof aluminium enclosures are rated type 4/4X, IP66/67.
Request a quote for this product
Junction Box Option
Beacon 1
Beacon 1 colour
Beacon 2
Beacon 2 colour
Beacon 3
Beacon 3 colour
Beacon 4
Beacon 4 colour
Alarm Horn Sounder
Voltage
Cable entries
Stopping plug/adaptor material
Guard/Tag material
Product version
Product option
Enclosure colour
Part Number:
D1xC3
Request Price or enquire about this product
Enquire about
Xenon/LED & Horn Alarm Bar

Description

The explosion proof D1xC3 alarm bar is comprised of up to 4 x D1xB2X05 5 Joule, D1xB2X10 10 Joule, D1xB2X15 15 Joule, D1xB2X21 21 Joule Xenon strobes or the D1xB2LD2 multi-function LED beacon with either a D1xS1F, D1xS1R, D1xS2F or D1xS2H alarm horn sounder with sound level outputs of up to 128dB(A). Factory assembled and pre-wired with or without a junction box, the signals are mounted on a 316 (A4) stainless steel plate with pole mount kit included.

Downloads

Datasheet Datasheet.pdf
Install Manual Alarm Horn with 1 beacon and junction box D226-01-128-IS_Issue_3.pdf
Install Manual Alarm Horn with 1 beacon no junction box D226-01-125-IS_Issue_3.pdf
Install Manual Alarm Horn with 2 beacons and junction box D226-01-138-IS_Issue_3.pdf
Install Manual Alarm Horn with 2 beacons no junction box D226-01-135-IS_Issue_3.pdf
Install Manual Alarm Horn with 3 beacons and junction box D226-01-148-IS_Issue_3.pdf
Install Manual Alarm Horn with 3 beacons no junction box D226-01-145-IS_Issue_3.pdf
Install Manual Alarm Horn with 4 beacons and junction box D226-01-158-IS_Issue_2.pdf
Install Manual Alarm Horn with 4 beacons no junction box D226-01-155-IS_Issue_2.pdf
Pole Mount Kit Installation Drawing D226-00-010_Issue_A.pdf
Declaration of Conformity DC-110_Issue_A_D1xC3_P2.pdf
Declaration of Conformity UKCA DC-111_Issue_A_D1xC3_P2_UKCA.pdf
Outline PDF Alarm Horn with 1 beacon and junction box D226-05-128_Issue_2.pdf
Outline PDF Alarm Horn with 1 beacon no junction box D226-05-125_Issue_3.pdf
Outline PDF Alarm Horn with 2 beacons and junction box D226-05-138_Issue_2.pdf
Outline PDF Alarm Horn with 2 beacons no junction box D226-05-135_Issue_2.pdf
Outline PDF Alarm Horn with 3 beacons and junction box D226-05-148_Issue_2.pdf
Outline PDF Alarm Horn with 3 beacons no junction box D226-05-145_Issue_2.pdf
Outline PDF Alarm Horn with 4 beacons and junction box D226-05-158_Issue_2.pdf
Outline PDF Alarm Horn with 4 beacons no junction box D226-05-155_Issue_2.pdf
Outline DWG Alarm Horn with 1 beacon and junction box D226-05-128_Issue_2.DWG
Outline DWG Alarm Horn with 1 beacon no junction box D226-05-125_Issue_3.DWG
Outline DWG Alarm Horn with 2 beacons and junction box D226-05-138_Issue_2.DWG
Outline DWG Alarm Horn with 2 beacons no junction box D226-05-135_Issue_2.DWG
Outline DWG Alarm Horn with 3 beacons and junction box D226-05-148_Issue_2.DWG
Outline DWG Alarm Horn with 3 beacons no junction box D226-05-145_Issue_2.DWG
Outline DWG Alarm Horn with 4 beacons and junction box D226-05-158_Issue_2.DWG
Outline DWG Alarm Horn with 4 beacons no junction box D226-05-155_Issue_2.DWG
Outline STEP Alarm Horn with 1 beacon and junction box D226-05-128_Issue_1_STEP.zip
Outline STEP Alarm Horn with 1 beacon no junction box D226-05-125_Issue_1_STEP.zip
Outline STEP Alarm Horn with 2 beacons and junction box D226-05-138_Issue_1_STEP.zip
Outline STEP Alarm Horn with 2 beacons no junction box D226-05-135_Issue_1_STEP.zip
Outline STEP Alarm Horn with 3 beacons and junction box D226-05-148_Issue_1_STEP.zip
Outline STEP Alarm Horn with 3 beacons no junction box D226-05-145_Issue_1_STEP.zip
Outline STEP Alarm Horn with 4 beacons and junction box D226-05-158_Issue_1_STEP.zip
Outline STEP Alarm Horn with 4 beacons no junction box D226-05-155_Issue_1_STEP.zip
Wiring PDF Alarm Horn with 1 beacon and junction box D226-06-128_Issue_4.pdf
Wiring PDF Alarm Horn with 1 beacon no junction box D226-06-125_Issue_4.pdf
Wiring PDF Alarm Horn with 2 beacons and junction box D226-06-138_Issue_4.pdf
Wiring PDF Alarm Horn with 2 beacons no junction box D226-06-135_Issue_4.pdf
Wiring PDF Alarm Horn with 3 beacons and junction box D226-06-148_Issue_4.pdf
Wiring PDF Alarm Horn with 3 beacons no junction box D226-06-145_Issue_4.pdf
Wiring PDF Alarm Horn with 4 beacons and junction box D226-06-158_Issue_4.pdf
Wiring PDF Alarm Horn with 4 beacons no junction box D226-06-155_Issue_4.pdf
Wiring PDF Product version [S] Alarm Horn with 1 beacon and junction box D226-06-628_Issue_1.pdf
Wiring PDF Product version [S] Alarm Horn with 1 beacon no junction box D226-06-625_Issue_1.pdf
Wiring PDF Product version [T] Alarm Horn with 1 beacon and junction box D226-06-728_Issue_1.pdf
Wiring PDF Product version [T] Alarm Horn with 1 beacon no junction box D226-06-725_Issue_1.pdf
Equipment Tag Drawing D254-00-111_Issue_1.pdf
Duty Label Drawing D254-00-041_Issue_1.pdf
Product image S2F horn with 1 beacon no junction box Red D1xC3N2xRS2F-R.png
Product image S2F horn with 1 beacon with junction box Grey D1xC3J2xAS2F-G.png
Product image S2F horn with 1 beacon with junction box Red D1xC3J2xRS2F-R.png
Product image S1F horn with 2 beacons no junction box Red D1xC3N2xGxRS1F-R.png
Product image S2F horn with 2 beacons no junction box Grey D1xC3N2xBxAS2F-G.png
Product image S2F horn with 2 beacons with junction box Red D1xC3J2xAxRS2F-R-2.png
Product image S2F horn with 2 beacons with junction box Grey D1xC3J2xAxRS2F-G.png
Product image S2F horn with 3 beacons no junction box Red D1xC3N2xGxAxRS2F-R.png
Product image S2F horn with 3 beacons no junction box Grey D1xC3N2xGxAxRS2F-G.png
Product image S2F horn with 4 beacons with junction box Red D1xC3J2xYxBxAxRS2F-R.png
Product image S1F horn with 4 beacon with junction box Grey D1xC3J2xBxAxRS1F-G.png

Features

  • Globally approved to UL, cUL, IECEx and ATEX
  • Factory assembled cable loom – optional junction box
  • Robust, corrosion proof marine grade aluminium enclosures
  • 316 (A4) stainless steel mounting plate
  • 316 (A4) stainless steel beacon guards
  • UV stable PC field replaceable lens colour filter
  • Ingress protection 4/4X/13/3R, IP66/67
  • Automatic synchronisation
  • Multiple wiring configurations available
  • SIL1/SIl2 (Route 2H) compliant
  • Version SIL2 (Route 1H) compliant with diagnostics
  • Telephone/Relay initiate version available

Specification

Beacon Option: D1xB2X05/10/15/21 Xenon Strobe Beacons
Product data: D1xB2X05: www.e2s.com/1-21-202
D1xB2X10: www.e2s.com/1-21-203
D1xB2X15: www.e2s.com/1-21-204
D1xB2X21: www.e2s.com/1-21-205
Flash rate: DC: 1Hz (60fpm), 1.5Hz (90fpm) & double flash
AC: 1Hz (60fpm)
Eff. Intensity cd: D1xB2X05: 156.65cd
D1xB2X10: 645.21cd
D1xB2X15: 731.71cd
D1xB2X21: 1250.66cd [Measured ref to I.E.S]
Peak cd: D1xB2X05: 250cd
D1xB2X10: 500cd
D1xB2X15: 750cd
D1xB2X21: 1050cd [Calculated from energy (J)]

Beacon Option:

D1xB2LD2 LED Beacon
Product data: D1xB2LD2: www.e2s.com/1-21-206
Source: Array of 4 x High Power Cree® LED’s
Modes: 1Hz flash (60 fpm), 1.5Hz (90 fpm), 2Hz (120 fpm)
Double strike flash, Triple strike flash
High Power Steady, Low Power Steady
Eff. Intensity cd: 174 cd – High Power Steady
Eff. Intensity cd: 338 cd – 1Hz flash

Alarm Horn:

D1xS1F/S1R/S2F/S2H Alarm Horn Sounders
Product data: D1xS1F: www.e2s.com/1-22-140
D1xS1R: www.e2s.com/1-22-145
D1xS2F: www.e2s.com/1-22-150
D1xS2H: www.e2s.com/1-22-155
Max. SPL: D1xS1F: 115dB(A) @ 1m [106dB(A) @ 10ft]
D1xS1R: 110dB(A) @ 1m [101dB(A) @ 10ft]
D1xS2F: 123dB(A) @ 1m [114dB(A) @ 10ft]
D1xS2H: 128dB(A) @ 1m [119dB(A) @ 10ft]
Nom. SPL +/- 3dB: D1xS1F: 110dB(A) @ 1m [101dB(A) @ 10ft]
D1xS1R: 105dB(A) @ 1m [96dB(A) @ 10ft]
D1xS2F: 118dB(A) @ 1m [109dB(A) @ 10ft]
D1xS2H: 126dB(A) @ 1m [117dB(A) @ 10ft]
No. of tones: 64 (UKOOA / PFEER compliant)
No. of stages: 4 – Positive or Negative stage switching
Volume control: Full range

J/Box option:

D1xJ2 Ex d Junction Box
Product data: D1xJ2: www.e2s.com/1-25-025
Terminals: DIN Rail 12 × AKZ 2.5, Earth 4 × AKE 2.5

General:

Common component features:
Voltages: 24Vdc, 115Vac, 230Vac
Ingress protection: IP rating per EN60529:IP66/67
Type rating per UL50E/NEMA250:4/4X/3R/13
Safety Integrity Level: Product version A/B/C: SIL1 and SIL2 Route 2H
Product version S: SIL2 Route 1H with diagnostics SFF: >99%
Enclosure material: Marine grade aluminium LM6 – copper free
Chromated & powder coated – corrosion proof
Mounting plate: 316 (A4) Stainless Steel
Enclosure colour: Red or Grey, custom colours available on request
Enclosure finish: Chromate & powder coated finish
Mounting: 4" Pole mount kit included
Lens material: Borosilicate glass dome & PC colour filter
Lens guard: 316 (A4) Stainless Steel dome guard as standard
Stopping plugs: Brass/Nickel Plated/Stainless Steel plugs included
Grounding stud: M5
Line monitoring: Blocking diode included. EOL can be factory fitted

Current Consumption

Voltage: D1xB2LD2 LED
Beacon Component
Nominal/Max. Current:
D1xB2X05 5J Xenon
Beacon Component
Nominal/Max. Current:
D1xB2X10 10J Xenon
Beacon Component
Nominal/Max. Current:
D1xB2X15 15J Xenon
Beacon Component
Nominal/Max. Current:
D1xB2X21 21J Xenon
Beacon Component
Nominal/Max. Current:
D1xS1R or F Alarm Horn
Sounder Component
Nominal/Max. Current:
D1xS2F Alarm Horn
Sounder Component
Nominal/Max. Current:
D1xS2H Alarm Horn
Sounder Component
Nominal/Max. Current:
24V dc
(20-28Vdc)
110mA/500mA 295mA/350mA 605mA/710mA 853mA/920mA 1130mA/1240mA 185mA/221mA 324mA/324mA 740mA/740mA
115-120Vac 50/60Hz 90mA/180mA 140mA/200mA 220mA/300mA 310mA/420mA 500mA/530mA 73mA/80mA 125mA/138mA 282mA/325mA
220-230Vac 50/60Hz 45mA/100mA 70mA/100mA 130mA/180mA 170mA/230mA 195mA/270mA 48mA/80mA 78mA/138mA 167mA/325mA

Part Codes

Part Code: Ident.: Description:
Product type: D1xC3 Alarm Bar Xenon Strobe or LED Beacons with Alarm Horn Sounder
Junction box option: N2
J2
No junction box – 316 Stainless Steel back plate
With D1xJ2 junction box – 316 Stainless Steel back plate
Beacon Type
(Add code for
each Beacon
required)
1Y
2Y
3Y
4Y
5Y
Y=Colour:

Note:
D1xB2X05 5 Joule Xenon Strobe Beacon
D1xB2X10 10 Joule Xenon Strobe Beacon
D1xB2X15 15 Joule Xenon Strobe Beacon
D1xB2X21 21 Joule Xenon Strobe Beacon
D1xB2LD2 LED Beacon
A: Amber B: Blue C: Clear G: Green
M: Magenta R: Red Y: Yellow
D1xB2X21 only available in first beacon position with J2 Junction Box option
Alarm Horn Sounder: S1F
S1R
S2F
S2H
D1xS1F alarm horn sounder – 115dB(A)
D1xS1R alarm horn sounder – 110dB(A)
D1xS2F alarm horn sounder – 123dB(A)
D1xS2H alarm horn sounder – 128dB(A)
Voltage: DC024
AC115
AC230
24Vdc
115-120Vac 50/60Hz
220-230Vac 50/60Hz
Cable entries: [e] M
A
B
C
D
E
F
G
1 × 3/4" NPT + 1 x M20x1.5mm – Default
1 x M20x1.5mm + 1 x M20 – adaptor
2 × 1/2” NPT – adaptors
1 × 3/4" NPT + 1 × 3/4" NPT – adaptor
2 x M25x1.5mm – adaptors
1 × 1/2" NPT – adaptor + 1 x M20x1.5mm
1 × 1/2" NPT – adaptor + 1 × 3/4" NPT
1 x M25x1.5mm – adaptor + 1 x M20
Stopping plug/Adaptor material: [m] B
N
S
Brass
Nickel Plated
Stainless Steel
Guard/Tag material: [s] 1
2
3
4
5
316 St/St Guard & 316 Equipment Tag
As (1) with Traffic Light Cowl
316 St/St Guard & 316 Equip. Tag & Duty Labels
As (5) with Traffic Light Cowl
316 St/St Guard & 316 Equip. Tag & Duty Labels attached by steel wire
Product version: [v] A
B
C
S
T
Note:
IECEx/ATEX/UL/cUL Class I Zone 1
IECEx/ATEX
UL/cUL Class I Div 1
SIL2 Route 1H IECEx/ATEX/UL/cUL Class I Zone 1
Relay/Telephone Initiation IECEx/ATEX
Product versions S & T only available on single beacon assemblies
Product option: [o] 1
2
3
4
5
6
W
X
Note:
Standard Wiring (Positive stage switching)
Independent Wiring (Positive stage switching)
Alt. Standard Wiring (Negative stage switching)
Independent Wiring (Negative stage switching)
Beacons & Sounder Linked w/ Line Monitoring
Independent Wiring w/ Line Monitoring
Special Wiring
Custom Configuration
Options are product specific, please review wiring drawings
Enclosure colour: [x] R
G
Red
Grey
Example: D1xC3 J2 5G 2A 2R S1F DC024 A B 1 A 1 R
D1xC3 Alarm bar assembly with D1xJ2 Junction Box, 1 x D1xB2LD2 LED beacon with green lens, 1 x D1xB2X10 10J Xenon beacon with Amber lens, 1 x D1xB2X10 10J Xenon beacon with red lens, D1xS1F Alarm Horn Sounder, 2 x M20x1.5 entry with brass stopping plugs, IECEx, ATEX, UL/cUL Class I Zone 1 approved with red enclosure

Approvals

  • IECEx
  • ATEX
  • UL
  • cUL
  • ULC
  • UKCA
  • CSFM
  • SIL1/2

Coding

  • NEC/CEC Class/Div:
    Class I Div 1 Group ABCD T3B/T3C/T4 Ta -55°C to +80°C (AC: +55°C)
  • NEC Class/Zone:
    Class I Zone 1 AEx db IIC T3/T4 Ta -55°C to +80°C (AC: +60°C)
  • CEC Class/Zone:
    Ex db IIC T3/T4 Ta -55°C to +80°C (AC: +60°C)
  • IECEx/ATEX:
    II 2G Ex db IIC T3/T4/T5 Gb Ta -55°C to +75°C (AC: +65°C)
    II 2D Ex tb IIIC T169°C Db Ta -55°C to +75°C (AC: T141°C +60°C)
    Coding dependent upon assembly contents, see component product details

Effective Candela lens colour factor

Amber Blue Clear Green Magenta Red Yellow
0.59 0.27 1.00 0.51 0.34 0.15 0.85

Tone Table

Stage 1 WAV file Frequency Description. Stage 2 Stage 3 Stage 4
T 1 /system/1/assets/files/000/000/405/405/214ccf82a/original/TF037.WAV 1000 Continuous – PFEER Toxic Gas Any T 2 T 44
T 2 /system/1/assets/files/000/000/386/386/ceb4e488c/original/TF009.WAV 1200/500 @ 1Hz Sweeping – DIN / PFEER P.T.A.P. Any T 3 T 44
T 3 /system/1/assets/files/000/000/412/412/fa8b418f9/original/TF045.WAV 1000 @ 0.5Hz (1s on, 1s off) Intermittent – PFEER Gen. Alarm Any T 2 T 44
T 4 /system/1/assets/files/000/000/383/383/11797b764/original/TF019.WAV 1.4KH-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s – NF C 48-265 Any T 24 T 1
T 5 /system/1/assets/files/000/000/382/382/2c2978b6a/original/TF017.WAV 544(100mS)/440 (400mS) – NF S 32-001 Any T 19 T 1
T 6 /system/1/assets/files/000/000/947/947/8f040484a/original/TF053.wav 1500/500 – (0.5s on , 0.5s off) x3 + 1s gap – AS4428 Any T 44 T 1
T 7 /system/1/assets/files/000/000/944/944/890010fd0/original/TF054.wav 500-1500Hz Sweeping 2 sec on 1 sec off – AS4428 Any T 44 T 1
T 8 /system/1/assets/files/000/000/417/417/abf396de0/original/TF003.WAV 500/1200Hz @ 0.26Hz(3.3s on, 0.5s off) – NEN 2575 Any T 24 T 35
T 9 /system/1/assets/files/000/000/953/953/5deedc543/original/TF055.wav 1000 (1s on, 1s off)x7 + (7s on, 1s off) – IMO Code 1a Any T 34 T 1
T 10 /system/1/assets/files/000/000/952/952/3a041fde3/original/TF056.wav 1000 (1s on, 1s off)x7 + (7s on, 1s off) – IMO Code 1a Any T 34 T 1
T 11 /system/1/assets/files/000/000/946/946/761de34c6/original/TF057.wav 420(0.5s on, 0.5s off)x3 + 1s gap – ISO 8201 Temporal Any T 1 T 8
T 12 /system/1/assets/files/000/000/945/945/689d9405a/original/TF058.wav 1000(0.5s on, 0.5s off)x3 + 1s gap – ISO 8201 Temporal Any T 1 T 8
T 13 /system/1/assets/files/000/000/950/950/2d337d14e/original/TF059.wav 422/775 – (0.85 on, 0.5 off) x3 + 1s gap – NFPA Temporal Any T 1 T 8
T 14 /system/1/assets/files/000/000/399/399/84b54dafb/original/TF034.WAV 1000/2000 @ 1Hz – Singapore Any T 3 T 35
T 15 /system/1/assets/files/000/000/393/393/744c6f53f/original/TF030.WAV 300 Continuous Any T 24 T 35
T 16 /system/1/assets/files/000/000/391/391/5f7a58b54/original/TF028.WAV 440 Continuous Any T 24 T 35
T 17 /system/1/assets/files/000/000/948/948/c697b364a/original/TF060.wav 470 Continuous Any T 24 T 35
T 18 /system/1/assets/files/000/000/949/949/7e429e658/original/TF061.wav 500 Continuous – IMO code 2 (Low) Any T 24 T 35
T 19 /system/1/assets/files/000/000/390/390/10abe0caa/original/TF027.WAV 554 Continuous Any T 24 T 35
T 20 /system/1/assets/files/000/000/384/384/5c30f9f4d/original/TF020.WAV 660 Continuous Any T 24 T 35
T 21 /system/1/assets/files/000/000/380/380/06feaa7b3/original/TF015.WAV 800 Continuous – IMO code 2 (High) Any T 24 T 35
T 22 /system/1/assets/files/000/000/406/406/49b88184e/original/TF043.WAV 1200 Continuous Any T 24 T 35
T 23 /system/1/assets/files/000/000/407/407/ecce63f4f/original/TF038.WAV 2000 Continuous Any T 3 T 35
T 24 /system/1/assets/files/000/000/421/421/b578af8a9/original/TF005.WAV 2400 Continuous Any T 20 T 35
T 25 /system/1/assets/files/000/000/951/951/d9ce2b2c6/original/TF062.wav 440 @ 0.83Hz (0.60s on, 0.60s off) Intermittent Any T 44 T 8
T 26 /system/1/assets/files/000/000/954/954/b703d99f1/original/TF063.wav 470 @ 0.9Hz (0.55s on, 0.55s off) Intermittent Any T 44 T 8
T 27 /system/1/assets/files/000/000/955/955/0f602886a/original/TF064.wav 470 @ 5Hz (0.10s on, 0.10s off) Intermittent Any T 44 T 8
T 28 /system/1/assets/files/000/000/956/956/dbb5f64db/original/TF065.wav 544 @ 1.14Hz (0.43s on, 0.44s off) Intermittent Any T 24 T 8
T 29 /system/1/assets/files/000/000/957/957/7bd3d8c1c/original/TF066.wav 655 @ 0.875Hz (0.57s on, 0.57s off) Intermittent Any T 44 T 8
T 30 /system/1/assets/files/000/000/397/397/d6d84d0c3/original/TF018.WAV 660 @ 0.28Hz (1.80s on, 1.80s off) Intermittent Any T 24 T 8
T 31 /system/1/assets/files/000/000/381/381/93f51c79a/original/TF016.WAV 660 @ 3.3Hz (0.15s on, 0.15s off) Intermittent Any T 24 T 8
T 32 /system/1/assets/files/000/000/410/410/a0f0ba2a6/original/TF033.WAV 745 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T 24 T 8
T 33 /system/1/assets/files/000/000/379/379/51c1bb5a9/original/TF014.WAV 800 (0.25s on, 1.00s off) Intermittent Any T 24 T 8
T 34 /system/1/assets/files/000/000/388/388/b4cf9203e/original/TF023.WAV 800 @ 2Hz (0.25s on, 0.25s off) – IMO code 3.a (High) Any T 24 T 8
T 35 /system/1/assets/files/000/000/377/377/ac5498db0/original/TF011.WAV 1000 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T 24 T 8
T 36 /system/1/assets/files/000/000/378/378/6380218ec/original/TF013.WAV 2400 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T 24 T 8
T 37 /system/1/assets/files/000/000/958/958/a90e62da4/original/TF067.wav 2900 @ 5Hz (0.10s on, 0.10s off) Intermittent Any T 24 T 8
T 38 /system/1/assets/files/000/000/959/959/f34b52faa/original/TF068.wav 363/518 @ 1Hz (0.50s / 0.50s) Alternating Any T 8 T 19
T 39 /system/1/assets/files/000/000/960/960/368703340/original/TF069.wav 450/500 @ 2Hz (0.25s / 0.25s) Alternating Any T 8 T 19
T 40 /system/1/assets/files/000/000/385/385/a85a0a356/original/TF021.WAV 554/440 @ 1Hz (0.50s / 0.50s) Alternating Any T 24 T 19
T 41 /system/1/assets/files/000/000/961/961/be2680966/original/TF070.wav 554/440 @ 0.65Hz (0.76s / 0.76s) Alternating Any T 8 T 19
T 42 /system/1/assets/files/000/000/962/962/314fe8a1b/original/TF071.wav 561/760 @ 0.83Hz (0.60s / 0.60s) Alternating Any T 8 T 19
T 43 /system/1/assets/files/000/000/963/963/5f6deb8a1/original/TF072.wav 780/600 @ 0.96Hz (0.52s / 0.52s) Alternating Any T 8 T 19
T 44 /system/1/assets/files/000/000/419/419/e353c86c4/original/TF002.WAV 800/1000 @ 2Hz (0.25s / 0.25s) Alternating Any T 24 T 19
T 45 /system/1/assets/files/000/000/419/419/e353c86c4/original/TF002.WAV 970/800 @ 2Hz (0.25s / 0.25s) Alternating Any T 8 T 19
T 46 /system/1/assets/files/000/000/375/375/771bd7a3e/original/TF012.WAV 800/1000 @ 0.875Hz (0.57s / 0.57s) Alternating Any T 24 T 19
T 47 /system/1/assets/files/000/000/374/374/021ee6540/original/TF010.WAV 2400/2900 @ 2Hz (0.25s / 0.25s) Alternating Any T 24 T 19
T 48 /system/1/assets/files/000/000/965/965/e3d76c24c/original/TF073.wav 500/1200 @ 0.3Hz (1.67s / 1.67s) Sweeping Any T 24 T 12
T 49 /system/1/assets/files/000/000/964/964/4e1cd3f7f/original/TF074.wav 560/1055 @ 0.18Hz (2.73s / 2.73s) Sweeping Any T 24 T 12
T 50 /system/1/assets/files/000/000/966/966/a8e5f4440/original/TF075.wav 560/1055 @ 3.3Hz (0.15s / 0.15s) Sweeping Any T 24 T 12
T 51 /system/1/assets/files/000/000/969/969/5734194b1/original/TF076.wav 600/1250 @ 0.125Hz (4s / 4s) Sweeping Any T 24 T 12
T 52 /system/1/assets/files/000/000/394/394/1bfee2f1b/original/TF031.WAV 660/1200 @ 1Hz (0.50s / 0.50s) Sweeping Any T 24 T 12
T 53 /system/1/assets/files/000/000/420/420/50f9ee7a7/original/TF004.WAV 800/1000 @ 1Hz (0.50s / 0.50s) Sweeping Any T 24 T 12
T 54 /system/1/assets/files/000/000/392/392/68d5d1294/original/TF029.WAV 800/1000 @ 7Hz (0.07s / 0.07s) Sweeping Any T 24 T 12
T 55 /system/1/assets/files/000/000/389/389/68683d240/original/TF024.WAV 800/1000 @ 50Hz (0.01s / 0.01s) Sweeping Any T 24 T 12
T 56 /system/1/assets/files/000/000/422/422/42b72dd93/original/TF006.WAV 2400/2900 @ 7Hz (0.07s / 0.07s) Sweeping Any T 24 T 12
T 57 /system/1/assets/files/000/000/373/373/a686b0abe/original/TF007.WAV 2400/2900 @ 1Hz (0.50s / 0.50s) Sweeping Any T 24 T 12
T 58 /system/1/assets/files/000/000/398/398/7c1bf5e00/original/TF025.WAV 2400/2900 @ 50Hz (0.01s / 0.01s) Sweeping Any T 24 T 12
T 59 /system/1/assets/files/000/000/967/967/2e92dbc46/original/TF077.wav 2500/3000 @ 2Hz (0.25s / 0.25s) Sweeping Any T 24 T 12
T 60 /system/1/assets/files/000/000/968/968/5dfcb9aea/original/TF078.wav 2500/3000 @ 7.7Hz (0.65s / 0.65s) Sweeping Any T 24 T 12
T 61 /system/1/assets/files/000/000/408/408/e0fadcdd2/original/TF042.WAV 800Hz Motor Siren Any T 24 T 12
T 62 /system/1/assets/files/000/000/404/404/1c1741943/original/TF041.WAV 1200Hz Motor Siren Any T 24 T 12
T 63 /system/1/assets/files/000/000/409/409/590aa5e82/original/TF044.WAV 2400Hz Motor Siren Any T 24 T 12
T 64 /system/1/assets/files/000/000/395/395/631e82dc8/original/TF026.WAV Simulated Bell Any T 21 T 12
For Stage 2 any Stage 1 alarm tone sound can be selected.
Country specific or custom tone configurations and alarm frequencies are available upon request.

Upcoming Events