New intrinsically safe versions of GNExCP7 and STExCP8 call points
- New H1 range of heat detectors for hazardous areas
- D1x explosion proof sounder and beacon achieve EN54 CPR, MED and DNV approval
- New intrinsically safe versions of GNExCP7 and STExCP8 call points
- Class I Zone 1 and Div 2 approval for STExCP8 call point range
- New D2x range Div 2 and Zone 2 alarm horns and speakers
- New loudspeaker versions plus approval upgrade
- STEx range extension of DNV type approval
- Next generation SIL rated warning signals
- New & Upgraded Alarm Horn Sounders - D1xS
- New & Upgraded Xenon & LED Beacons - GNExB2 & STExB2
- New & Upgraded Alarm Horn Sounders - GNExS & STExS
- AlertAlarm, AlertAlight & Sonora product series upgrade
- M series upgrade - new alarm horn sounder electronics in IP66/67 Type 4/4X/13 enclosures
- E2S upgrades its signaling beacons with super bright outputs and additional configuration options
- The world’s most extensive range of MCPs has been improved – again
- E2S launches the brightest ever hazardous location UL1971 LED fire alarm beacon
- E2S major on hazardous area integrated warning device assemblies at ADIPEC
- D1xB2 explosion proof SIL2 signals at NFPA 2019
- STEx 316 stainless steel signals - DNV approved
- New D1xB2 beacons launched at OTC 2019
- STExCP8 call points - now SIL2 compliant
- E2S exhibits at ADIPEC 2018
- D2x LED & Xenon beacons - next gen UL1971 signals
- Global GRP - the GNEx solution
- The brightest lights at NFPA 2018
New intrinsically safe versions of GNExCP7 and STExCP8 call points
The E2S Warning Signals GNExCP7 and STExCP8 range of manual call points and push buttons are now available as intrinsically safe devices. Certified by UL for Class I Div 1 Group ABCD and Class I Zone 0 AEx ia IIC applications to NEC and CEC codes and Ex ia IIC to IECEx and ATEX standards. DNV approval for use in exposed locations to IEC60945 assures suitability for the harshest of marine environments. Both ranges are also SIL2 compliant to IEC61508.
The new intrinsically safe ‘I’ product version of the GNExCP7 range features a robust GRP (glass reinforced polyester) enclosure, whilst the STExCP8 range employs a 316L stainless steel enclosure.
The GNExCP7-BG-I and STExCP8-BG-I break glass variants for fire alarm initiation or suppression release the are supplied with safety glass and optional stainless steel lift flap.
The GNExCP7-PT-I and STExCP8-PT-I provide a a locking push button mechanism that requires a tool reset, ideal for process shutdown.
The GNExCP7-PM-I and STExCP8-PM-I are configured to provide a momentary switch for applications such as alarm acknowledge.
The GNExCP7-PB-I and STExCP8-PB-I product variants feature a robust button that must be rotated before it can be pushed; essential when preventing accidental activation, for example of CO2 release.
All variants are available with DIN rail terminals or, if EOL and series resistors are required, the innovative PCBA termination board. The PCBA termination provides separate connections for EOL and/or series devices or the optional LED indicator, enabling the field installation of line monitoring devices without the need to remove system cabling.
Please contact your local representative or E2S salesperson for further information.